Publikováno v:
Medical Physics. 22:1581-1593
Measurements were made of the MTF(f), NPS(f), and DQE(f) of four generations of computed radiography (CR) imaging plates and three generations of CR image readers. The MTF generally showed only a minor change between generations of plates and readers
Publikováno v:
Medical Physics. 21:175-184
Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim un
Autor:
F. Kelcz, W. K. Sze, D.E. Brown, David P. Naidich, Charles A. Mistretta, R.T. Bystrianyk, D. L. Ergun
Publikováno v:
Radiology. 174:243-249
Recent reports have emphasized the potential for dual-energy computed radiographic applications. An improved method for single-exposure material-selective imaging with a photostimulable phosphor computed radiography system was investigated. The essen
Autor:
R, Fahrig, K, Butts, J A, Rowlands, R, Saunders, J, Stanton, G M, Stevens, B L, Daniel, Z, Wen, D L, Ergun, N J, Pelc
Publikováno v:
Journal of magnetic resonance imaging : JMRI. 13(2)
A system enabling both x-ray fluoroscopy and MRI in a single exam, without requiring patient repositioning, would be a powerful tool for image-guided interventions. We studied the technical issues related to acquisition of x-ray images inside an open
Autor:
James T. Dobbins, Raymond J. Althof, Erwin B. Bellers, Yi Wang, Marco G.J. Wind, Walter W. Peppler, F. E. Zink, Frederik Jan De Bruijn, David G. Kruger, D. L. Ergun, F. Kelcz
Publikováno v:
SPIE Proceedings.
We have reported on a single-exposure dual-energy system based on computed radiography (CR) technology. In a clinical study conducted over a two year period, the dual-energy system proved to be highly successful in improving the detection (p=0.0005)
We evaluated a single-exposure, phosphor-plate, dual-energy imaging device that produces, in addition to conventional chest radiographs, both tissue- and bone-selective images. Our purpose was to determine whether dual-energy radiography was more acc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b8b907c31fcb3328dced7160843622dd
Publikováno v:
Investigative Radiology. 25:1373
Publikováno v:
Medical Physics. 8:629-639
Theoretical and experimental techniques have been used to study optimal x-ray for screen-film mammography. A simple model of mammographic imaging predicts optimum x-ray energies which are significantly higher than the K-characteristic energies of Mo.
Autor:
P D Myerowitz, D. L. Ergun, William C. Zarnstorff, M. S. Van Lysel, Andrew B. Crummy, Charles A. Mistretta, C. G. Shaw
Publikováno v:
Radiology. 142:209-213
The logarithmic amplification of video signals and the availability of data in digital form make digital subtraction videoangiography a suitable tool for videodensitometric estimation of physiological quantities. A system for this purpose was impleme
Autor:
William C. Zarnstorff, J F Sackett, Charles A. Mistretta, D. L. Ergun, M. S. Van Lysel, C. G. Shaw, William D. Turnipseed, D. Myerowitz, Charles M. Strother, Andrew B. Crummy, Robert A. Kruger
Publikováno v:
IEEE Transactions on Nuclear Science. 27:1042-1046
During the past several years, we have developed dedicated digital algorithms for real time processing of X-ray transmission imaging data obtained from an image intensifier television fluoroscopy system. Three imaging modes called Mask Mode Fluorosco