Zobrazeno 1 - 10
of 161
pro vyhledávání: '"D. J. Melvold"'
Autor:
J.B. Posey, J. L. Koepfinger, D.W. Lenk, D. Worden, D. J. Melvold, S.G. Whisenant, R. Odenberg, K. B. Stump, R.S. Thallam, G.E. Lee, D. Dawson
Publikováno v:
IEEE Transactions on Power Delivery. 10:1285-1300
This is the second and continuation of the metal oxide surge arresters bibliography first published in IEEE Transactions on Power Delivery, vol. 8, no. 3, p.1000-34, 1991. This listing covers publications from 1990-1992. Some changes were made in thi
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. 95:829-838
A fast-acting HVDC Circuit Breaker was tested on the Pacific HVDC Intertie System. The Intertie was operated as a three-terminal system with the breaker located on one branch. Intentional faults were applied close to the breaker and 250 miles away an
Autor:
D. J. Melvold, D. R. Penn
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :1081-1087
In conjunction with a recent proqram to determine and sutstantiate a higher continuous transmission and conversion capacity of the Pacific HVDC Intertie System, a program of scheduled continuous overloadings was implemented. The larqe power converter
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :564-572
The operation of the Sylmar HVDC Converter Station has generated interference voltages in the carrier frequency range. Especially a 24 kHz oscillation has caused interference with carrier-type line protection in the ac system as well as with equipmen
Autor:
D. J. Melvold, S. A. Miske
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :3974-3982
Surge arresters are being installed in proximity to HV underground cable circuits. Cable circuits, due to their relatively high capacitance and low surge impedance, can impose a severe duty on an arrester. This paper presents the results of a study u
Autor:
T. C. Cheng, D. J. Melvold
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :655-666
The unavailability of high-voltage pipe- type cable for impulse propagation tests has hindered the development of creditable models for si'mulation studies. Low-voltage field tests have been conducted on a 13.9 km9 230 kV cable and subsequent analysi
Autor:
W. D. Niebuhr, D. E. Hedman, D. C. Bacvarov, D. J. Melvold, J. L. Koepfinger, R. A. Jones, C. L. Ballentine, G.Y.R. Allen, A. Fakheri, F. G. Berg, E. Yasuda, K. B. Stump, F. A. Fisher, R. G. Black, E. R. Taylor, J. Andersen
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :4033-4040
This report presents a simplified silicon-carbide surge arrester model suitable for analog and digital studies of switching transients on overhead HV and EHV lines. The report also includes a guide for the application of the model in the selection of
Autor:
D. J. Melvold
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :690-701
This paper presents a summary of the decisions made and methods used to optimize the design of the ac filter bank for the Sylmar Terminal of the Pacific HVDC Intertie System, and the statistical approach used in the test techniques employed to evalua
Publikováno v:
IEEE Power Engineering Review. :25-26
This paper describes studies conducted by the Los Angeles Department of Water and Power to evaluate the dc filter and smoothing reactor performance requirements necessitated by upgrading the Pacific HVDC Intertie system from ±400 kV to ±500 kV.1 Th
Autor:
D. R. Penn, D. J. Melvold
Publikováno v:
IEEE Power Engineering Review. :31-31