Zobrazeno 1 - 10
of 49
pro vyhledávání: '"D. G. Murray"'
Autor:
D. G. Murray
Publikováno v:
British dental journal.
This opinion piece centres on my own journey through clinical education and reflects on my involvement in clinical undergraduate teaching. Utilising experiences teaching on undergraduate clinics, before and after attending the Advanced Certificate in
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Parasitology. 104:397-405
A 3000 bp cDNA insert (G6/1) from Giardia duodenalis, cloned into Escherichia coli is located on chromosome 3 of Giardia stocks which have 3 chromosomes detectable by field-inversion gel electrophoresis in the range 650–800 kb and on chromosome 3 a
Autor:
D. G. Murray
Publikováno v:
Total Knee Arthroplasty ISBN: 3540202420
Medial unicompartmental knee arthroplasty (UKA) has many advantages over total arthroplasty (TKA) including better function and less morbidity. However, the longterm failure rates of many designs of fixed-bearing UKA are high because of polyethylene
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2ebeb8511429569044178aa9a594c1ea
https://doi.org/10.1007/3-540-27658-0_51
https://doi.org/10.1007/3-540-27658-0_51
Publikováno v:
Clinical orthopaedics and related research. (285)
Two sets of six fresh frozen autopsy specimens were used to test the quadriceps force requirements for knee extension after sequential distal-to-proximal and proximal-to-distal excisions of the patella. The quadriceps force as a function of knee flex
Publikováno v:
Instructional course lectures. 39
A review of our experience in total joint arthroplasty revealed that the cell saver was not cost-effective in the case of routine primary hip or knee replacement. Its use should be restricted to cases of revision hip and knee surgery in which infecti
Autor:
D. G. Murray, C. D. Smith
Publikováno v:
Canadian Journal of Civil Engineering. 2:437-446
This paper describes the concept and the experimental study made to determine the design criteria for a drop structure comprised entirely of loose dumped rock. The three principal components of the design were: (1) the weir at the top of the slope, (
Publikováno v:
Tetrahedron Letters. 15:1961-1964
Autor:
D G Murray
Publikováno v:
The Journal of Bone & Joint Surgery. 64:1108-1113
Publikováno v:
Journal of Orthopaedic Research. 4:37-44
Previous experiments have suggested that mechanical activity of electrode implants may contribute to the observed bone formation that has been attributed to the electrical currents. This was tested by implanting movable and stationary wires in the me