Zobrazeno 1 - 10
of 16
pro vyhledávání: '"D. Cody Morris"'
Autor:
Brian S. Garra, Pengfei Song, Timothy J. Hall, Todd N. Erpelding, Stephen J. Rosenzweig, Stephen A. McAleavey, Mark L. Palmeri, Matthew W. Urban, Richard L. Ehman, Gilles Guenette, Glen McLaughlin, Mathieu Couade, Véronique Miette, Shigao Chen, Ted Lynch, Michael MacDonald, Hua Xie, Paul L. Carson, Manish Dhyani, D. Cody Morris, Lindsey C. Carlson, Yoko Okamura, Derek Y. Chan, Yufeng Deng, Arinc Ozturk, Michael H. Wang, Zaegyoo Hah, Nancy A. Obuchowski, Richard G. Barr, Ned C. Rouze, Jun Chen, Anthony E. Samir, Vijay Shamdasani, Shana Fielding, Keith A. Wear, Andy Milkowski, David J. Napolitano, Bo Qiang, Kathryn R. Nightingale, Ravi Managuli, Siyun Yang, Gee Albert, Kingshuk Roy Choudhury, Yuling Chen
Publikováno v:
J Ultrasound Med
OBJECTIVES—: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms. METHODS—: Two elast
Autor:
Jonathan Mamou, D. Cody Morris, Wen-Chi Foo, Hong Chen, Kathryn R. Nightingale, Mark L. Palmeri, Theresa H. Lye, Thomas J. Polascik, Jiaoti Huang, Derek Y. Chan
Publikováno v:
Ultrasound Med Biol
Diagnosing prostate cancer through standard transrectal ultrasound (TRUS)-guided biopsy is challenging because of the sensitivity and specificity limitations of B-mode imaging. We used a linear support vector machine (SVM) to combine standard TRUS im
Autor:
Jonathan Mamou, D. Cody Morris, Mark L. Palmeri, Derek Y. Chan, Theresa H. Lye, Thomas J. Polascik, Kathryn R. Nightingale
Publikováno v:
2021 IEEE International Ultrasonics Symposium (IUS).
This study presents a deep neural network (DNN) for generating a multiparametric ultrasound (mpUS) volume of the prostate by combining data from acoustic radiation force impulse (ARFI) imaging, shear wave elasticity imaging (SWEI), B-mode imaging, an
Publikováno v:
IEEE Trans Ultrason Ferroelectr Freq Control
Ultrasound elasticity imaging in soft tissue with acoustic radiation force requires the estimation of displacements, typically on the order of several microns, from serially acquired raw data A-lines. In this work, we implement a fully convolutional
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::64a8d6817d76159343921f7b5ff94002
https://europepmc.org/articles/PMC8363049/
https://europepmc.org/articles/PMC8363049/
Autor:
Thomas J. Polascik, Mark L. Palmeri, Derek Y. Chan, D. Cody Morris, Kathryn R. Nightingale, Wen-Chi Foo
Publikováno v:
Ultrasound Med Biol
Transrectal ultrasound (TRUS) B-mode imaging provides insufficient sensitivity and specificity for prostate cancer (PCa) targeting when used for biopsy guidance. Shear wave elasticity imaging (SWEI) is an elasticity imaging technique that has been co
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9ea05d342b13feb78887c9f685d794f9
https://europepmc.org/articles/PMC8169635/
https://europepmc.org/articles/PMC8169635/
Autor:
Jonathan Mamou, D. Cody Morris, Derek Y. Chan, Mark L. Palmeri, Theresa H. Lye, Thomas J. Polascik, Kathryn R. Nightingale
Publikováno v:
2020 IEEE International Ultrasonics Symposium (IUS).
This study demonstrates the application of multiparametric ultrasound (mpUS) imaging techniques for combining data from four individual modalities: acoustic radiation force impulse (ARFI) imaging, shear wave elasticity imaging (SWEI), B-mode imaging,
Publikováno v:
2019 IEEE International Ultrasonics Symposium (IUS).
Ultrasound elasticity imaging in soft tissue with acoustic radiation force requires extracting displacement information, typically on the order of several microns, from raw data. In this work, we implement a fully convolutional neural network for ult
Publikováno v:
The Journal of the Acoustical Society of America. 149:A19-A19
We will present a recent work on the development of an ultrasound system that provides co-registered 3-D acoustic radiation force impulse (ARFI) imaging, shear wave elasticity imaging (SWEI), and B-mode imaging volumes to guide a targeted biopsy of p
Autor:
Samantha L. Lipman, Derek Y. Chan, Ned C. Rouze, Kathryn R. Nightingale, Thomas J. Polascik, D. Cody Morris, Mark L. Palmeri
Publikováno v:
2018 IEEE International Ultrasonics Symposium (IUS).
This study demonstrates the implementation of a multiresolution shear wave tracking algorithm that enables elasticity imaging of prostate cancer and zonal anatomy. The combined ARFI/SWEI sequence uses closely-spaced push beams across the lateral fiel
Autor:
Jonathan Mamou, D. Cody Morris, Thomas J. Polascik, Daniel Rohrbach, Kathryn R. Nightingale, Mark L. Palmeri, Wen-Chi Foo, Hong Chen
Publikováno v:
The Journal of the Acoustical Society of America. 145:1859-1860
Transrectal ultrasound (TRUS) imaging is routinely performed to guide core-needle biopsies for the definitive diagnosis of prostate cancer (PCa). Needles are rigidly attached to the transducer and randomly sample the prostate yielding a high rate of