Zobrazeno 1 - 10
of 34
pro vyhledávání: '"D. Agoris"'
Publikováno v:
IEEE Transactions on Power Systems. 21:1574-1582
This paper describes an efficient computational methodology that can be used for calculating the appropriate strategy for load shedding protection in autonomous power systems. It extends an existing method that is based on the sequential Monte Carlo
Publikováno v:
Energy Policy. 34:1357-1366
The assessment of Renewables-to-Electricity Systems is a complex, time-consuming task and requires skilled, experienced engineers. This paper describes the on-going research effort that takes place in the development of a new Intelligent Approach, an
Autor:
F Siakkis, M Damassiotis, George Giannakidis, K Tigas, D Agoris, V Kilias, S Vassos, N Vassilakos
Publikováno v:
Energy Policy. 32:2019-2033
The current state of the Greek energy system is analysed together with alternative energy policies. A by sector analysis provides an overview of the inputs that have been used for this investigation. A combination of a demand forecast performed toget
Publikováno v:
IEEE Computer Applications in Power. 11:46-51
Graphical user interfaces (GUI) provide interactive and intuitive visual communication to power system analysis application programs, enhancing the capabilities of engineers to conduct studies with ease and flexibility. As a result, since the late 19
Publikováno v:
IEEE Transactions on Power Delivery. 11:519-525
The objective of this paper is to present an improved computational method for the overall reliability assessment of autonomous power systems that may or may not contain HVDC interconnection links. This is a hybrid method based on a Monte-Carlo simul
Publikováno v:
PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376).
Due to problems caused to electronic devices, fed by 220 V auxiliary circuit in a 400 kV substation of the Greek HV interconnected system, extensive measurements of overvoltages have been performed, correlated with the timing of switching operations
Publikováno v:
SAE Technical Paper Series.
Publikováno v:
11th International Symposium on High-Voltage Engineering (ISH 99).
The results of an experimental research concerning the factors affecting the position of interception of an electrical discharge in a composite gap when stressed by positive impulses are presented in this paper The test arrangement consisted of a woo
Δημοσίευση σε επιστημονικό περιοδικό Summarization: In this paper, an optimized fuzzy controller is presented for the control of the environmental parameters at the building zone level. The occupants’ preferences ar
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::10f0e744afd2fe2827a1edaa399b6ab8
Kniha
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.