Zobrazeno 1 - 10
of 47
pro vyhledávání: '"D A Taberner"'
Publikováno v:
ResearcherID
AIMS: To examine the reliability of international normalised ratio (INR) determination on samples stored as whole blood for up to two days at room temperature. METHODS: The INR of 40 patients receiving oral anticoagulants was determined on fresh bloo
Publikováno v:
Journal of Clinical Pathology. 50:783-789
AIMS: Errors in reporting International Normalised Ratios (INR) may be corrected by assignment of a System International Sensitivity Index (System ISI). This 57 centre study tests the validity of several procedures for INR correction. METHODS: Prothr
Publikováno v:
British Journal of Haematology. 96:435-441
Coagulometer-induced errors in International Normalized Ratios (INR) may be corrected by assigning an International Sensitivity Index (ISI) specific for the local combination of coagulometer and thromboplastin reagent (System ISI). In the present stu
Publikováno v:
Journal of Clinical Pathology. 50:40-44
AIMS: To determine the minimum number of calibrant plasmas required to assign an accurate System International Sensitivity Index (ISI). METHODS: Eighteen lyophilised adsorbed and eight frozen coumarin plasmas were despatched to 57 participating labor
Publikováno v:
British Journal of Haematology. 86:112-117
One hundred and twenty-nine centres in the U.K. participated in a study to test the reliability of the three methods of correction for coagulometer effects on international normalized ratios (INR). Results from 37 centres which tested three warfarini
Publikováno v:
La Ricerca in Clinica e in Laboratorio. 20:59-69
The international normalized ratios (INR) system allows valid comparisons in results and quality of performance to be made between users of different thromboplastin reagents. In the international quality control surveys currently over 80% of the 53 c
Autor:
L. J. Goodman, A. M. H. P. Van Den Besselaar, D. A. Taberner, Clarke K, Leon Poller, C. Van Rijn
Publikováno v:
Thrombosis and Haemostasis. 78:852-854
SummaryAdequate heat stability of international reference preparations (IRP) for thromboplastin (tissue factor) is an essential requirement. Accelerated degradation testing was performed by three laboratories on two candidate IRP for recombinant huma
Publikováno v:
International journal of clinical practice. 52(6)
We undertook a survey of 2555 outpatients (both new and review) to look at the reasons for high non-attendance (DNA) rates. Completed questionnaires (n = 983, 38.5% response) indicated the main reasons: forgetting or not receiving the appointment bec
Publikováno v:
Thrombosis and haemostasis. 78(2)
Adequate heat stability of international reference preparations (IRP) for thromboplastin (tissue factor) is an essential requirement. Accelerated degradation testing was performed by three laboratories on two candidate IRP for recombinant human tissu
Publikováno v:
Blood coagulationfibrinolysis : an international journal in haemostasis and thrombosis. 7(8)
Circulating levels of the adhesion molecule P-selectin (CD62P) are increased in the plasma of patients with atherosclerosis, but its relationship to the anatomical location of symptomatic disease or extent of symptomatic disease is unknown. The influ