Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Cyril Delattre"'
Autor:
Frédéric Mallard, Veronique Lanet, Denis Roller, Frederic Ginot, Bernard Calvas, Gilles Marchand, Raymond Campagnolo, Frédéric Foucault, Patrick Broyer, Cyril Delattre, Lionel Menou
Publikováno v:
Biomedical Microdevices. 10:35-45
Clinical diagnostics is one of the most promising applications for microfluidic lab-on-a-chip or lab-on-card systems. DNA chips, which provide multiparametric data, are privileged tools for genomic analysis. However, automation of molecular biology p
Autor:
Vijay Srinivasan, Arnaud Rival, Jairus Kleinert, Orlin D. Velev, Cyril Delattre, Vamsee K. Pamula
The operation of digital microfluidic devices with water droplets manipulated by electrowetting is critically dependent on the static and dynamic stability and lubrication properties of the oil films that separate the droplets from the solid surfaces
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e313dc787466ecd865ac092b9c6bfb28
https://europepmc.org/articles/PMC4441711/
https://europepmc.org/articles/PMC4441711/
Autor:
Cyril Delattre, Alain Glière
Publikováno v:
Sensors and Actuators A: Physical. :601-608
This work reports numerical and experimental investigations of capillary stop valves, which simply rely on the sudden expansion of a microchannel to control the liquid position. The simulation approach is based on the solution of the free surface equ
Publikováno v:
Journal of Catalysis. 209:401-412
A differential packed-bed reactor microfabricated in silicon is presented for heterogeneous gas phase catalyst testing. A novel cross-flow design achieves uniform flow distribution over a wide (25.5 mm) but shallow (400 μm long × 500 μm deep) cata
Publikováno v:
Sensors and Actuators B: Chemical. 82:297-306
A novel silicon microfabricated chemical reactor has been developed for testing catalyst particles relevant to chemical process applications. The reactor incorporates a cross-flow design with a short pass multiple flow-channel geometry enabled by mic
Autor:
Christine Peponnet, Cédric Allier, Yves Fouillet, Arnaud Rival, Frederic Bottausci, Denis Bouvier, Dorothée Jary, Guillaume Delapierre, Manuelle Quinaud, Cyril Delattre, Laurent Davoust
Publikováno v:
Biosensors & bioelectronics
Biosensors & bioelectronics, 2012, 36 (1), pp.230-235. ⟨10.1016/j.bios.2012.04.024⟩
Biosensors & bioelectronics, 2012, 36 (1), pp.230-235. ⟨10.1016/j.bios.2012.04.024⟩
International audience; Biological environmental monitoring (BEM) is a growing field of research which challenges both microfluidics and system automation. The aim is to develop a transportable system with analysis throughput which satisfies the requ
Gas-liquid selective oxidations with oxygen under explosive conditions in a micro-structured reactor
Autor:
Arnaud Leclerc, Claude de Bellefon, Cyril Delattre, Daniel Schweich, Patrick Pouteau, Mohamad Alame
Publikováno v:
Lab on a Chip
Lab on a Chip, Royal Society of Chemistry, 2008, 8 (5), pp.814-7. ⟨10.1039/b717985e⟩
Lab on a Chip, 2008, 8 (5), pp.814-7. ⟨10.1039/b717985e⟩
Lab on a Chip, Royal Society of Chemistry, 2008, 8 (5), pp.814-7. ⟨10.1039/b717985e⟩
Lab on a Chip, 2008, 8 (5), pp.814-7. ⟨10.1039/b717985e⟩
International audience; The gas-liquid oxidation of cyclohexane is performed at high temperature (>200 degrees C) and pressure (up to 25 bar) using pure oxygen in a Pyrex capped silicon etched microreactor which allows convenient screen reaction cond
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6712d848d47c6c01cbf766b6b1e510d2
https://hal.archives-ouvertes.fr/hal-00532911
https://hal.archives-ouvertes.fr/hal-00532911
Autor:
Gilles Marchand, Guy Tournier, Patrick Pouteau, Claude de Bellefon, Christophe Pijolat, Marilyne Roumanie, Valérie Meille, Frédérique Mittler, Cyril Delattre
Publikováno v:
The Chemical Engineering Journal
The Chemical Engineering Journal, 2008, 135 (Sup 1), pp.S317-S326. ⟨10.1016/j.cej.2007.07.053⟩
The Chemical Engineering Journal, Elsevier, 2008, 135 (Sup 1), pp.S317-S326. ⟨10.1016/j.cej.2007.07.053⟩
The Chemical Engineering Journal, 2008, 135 (Sup 1), pp.S317-S326. ⟨10.1016/j.cej.2007.07.053⟩
The Chemical Engineering Journal, Elsevier, 2008, 135 (Sup 1), pp.S317-S326. ⟨10.1016/j.cej.2007.07.053⟩
International audience; When surface-supported chemical reactions are performed in microsystems, high production rate cannot be obtained due to the intrinsically low surface area. Increasing the active surface area of silicon microsystems is a challe
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7022e98f43cee2d63077eed28dc48a31
https://hal-emse.ccsd.cnrs.fr/emse-00431657
https://hal-emse.ccsd.cnrs.fr/emse-00431657
Autor:
Valérie Meille, Patrick Pouteau, C. de Bellefon, Marilyne Roumanie, Cyril Delattre, Christophe Pijolat
Publikováno v:
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical, Elsevier, 2006, 118, pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
Sensors and Actuators B: Chemical, Elsevier, 2006, 118 (1-2), pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
Sensors and Actuators B: Chemical, 2006, 118, pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
Sensors and Actuators B: Chemical, 2006, 118 (1-2), pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
Sensors and Actuators B: Chemical, Elsevier, 2006, 118, pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
Sensors and Actuators B: Chemical, Elsevier, 2006, 118 (1-2), pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
Sensors and Actuators B: Chemical, 2006, 118, pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
Sensors and Actuators B: Chemical, 2006, 118 (1-2), pp.297-304. ⟨10.1016/j.snb.2006.04.035⟩
International audience; The study concerns a catalytic micro-reactor with the goal of gas detection. The objectives are: (i) to develop a silicon “micro-reactor” with its heater, (ii) to deposit catalysts in the micro-channels of the device, and
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5c9759db2379f68303e6fc2c2929c698
https://hal.archives-ouvertes.fr/hal-00091526
https://hal.archives-ouvertes.fr/hal-00091526
Publikováno v:
Analytical chemistry. 77(16)
Electrical monitoring of DNA hybridization is one way to reduce the cost and size of the DNA chip reader in comparison with the more classical optical detection. Within electrical methods, electrochemical detection shows very high performances in ter