Zobrazeno 1 - 10
of 1 162
pro vyhledávání: '"Curceanu C"'
Autor:
Sirghi F., Abbene L., Bazzi M., Bosnar D., Bragadireanu M., Buttacavoli A., Cargnelli M., Carminati M., Clozza A., Deda G., Del Grande R., Dulski K., De Paolis L., Fabbietti L., Fiorini C., Friščić I., Guaraldo C., Iliescu M., Iwasaki M., Khreptak A., Manti S., Marton J., Miliucci M., Moskal P., Napolitano F., Sgaramella F., Niedźwiecki S., Ohnishi H., Piscicchia K., Sada Y., Scordo A., Silarski M., Sirghi D., Skurzok M., Spallone A., Toho K., Tüchler M., Yoshida C., Zmeska J., Curceanu C.
Publikováno v:
EPJ Web of Conferences, Vol 291, p 01008 (2024)
The most important information still missing in the field of the low-energy antikaon-nucleon inter actions studies is the experimental determination of the hadronic energy shift and width of kaonic deuterium. This measurement will be performed by the
Externí odkaz:
https://doaj.org/article/f5fdb35a937c436f963c96441204b184
Autor:
De Paolis L., Abbene L., Bazzi M., Bettelli M., Borghi G., Bosnar D., Bragadireanu M., Buttacavoli A., Cargnelli M., Carminati M., Clozza A., Deda G., Del Grande R., Dulski K., Fiorini C., Friščić I., Guaraldo C., Iliescu M., Iwasaki M., Khreptak A., Manti S., Marton J., Miliucci M., Moskal P., Napolitano F., Niedzwiecki S., Obertova J., Ohnishi O., Piscicchia K., Principato F., Sada Y., Scordo A., Sgaramella F., Silarski M., Sirghi D.L., Sirghi F., Skurzok M., Wycech S., Spallone A., Toho K., Tüchler M., Yoshida C., Zappettini A., Zmeskal J., Curceanu C.
Publikováno v:
EPJ Web of Conferences, Vol 291, p 05003 (2024)
KAMEO (Kaonic Atoms Measuring Nuclear Resonance Effects Ob-servables) is a proposal for an experiment aiming to perform the first consistent measurement of the E2 nuclear resonance effects in kaonic molybdenum A=94,96,98,100 isotopes. The E2 nuclear
Externí odkaz:
https://doaj.org/article/94be8cfe825d417190b9c5661d43a39a
Autor:
Coussat, A., Krzemien, W., Baran, J., Parzych, S., Beyene, E., Chug, N., Curceanu, C., Czerwiński, E., Das, M., Dulski, K., Eliyan, K. V., Jasińska, B., Kacprzak, K., Kapłon, Ł., Klimaszewski, K., Korcyl, G., Kozik, T., Kubat, K., Kumar, D., Vendan, A. Kunimal, Lisowski, E., Lisowski, F., Mędrala-Sowa, J., Moyo, S., Mryka, W., Niedźwiecki, S., Pandey, P., del Rio, E. Perez, Raczyński, L., Rädler, M., Sharma, S., Skurzok, M., Stępień, E. Ł., Tayefi, K., Tanty, P., Wiślicki, W., Moskal, P.
In positron emission tomography acquisition (PET), sensitivity along a line of response can vary due to crystal geometrical arrangements in the scanner and/or detector inefficiencies, leading to severe artefacts in the reconstructed image. To mitigat
Externí odkaz:
http://arxiv.org/abs/2410.00669
Autor:
Dulski, K., Beyene, E., Chug, N., Curceanu, C., Czerwiński, E., Das, M., Gorgol, M., Jasińska, B., Kacprzak, K., Kapłon, Ł., Korcyl, G., Kozik, T., Kubat, K., Kumar, D., Lisowski, E., Lisowski, F., Mędrala-Sowa, J., Niedźwiecki, S., Pandey, P., Parzych, S., del Rio, E. Perez, Rädler, M., Sharma, S., Skurzok, M., Tayefi, K., Tanty, P., Stępień, E. Ł., Moskal, P.
Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the annihilation of a positron and an electron. Mean positron lifetime in
Externí odkaz:
http://arxiv.org/abs/2409.07963
Autor:
Achenbach, P., Aoki, K., Aoki, S., Curceanu, C., Diehl, S., Doi, T., Endo, M., Fujita, M., Fukuda, T., Garcia-Tecocoatzi, H., Geng, L. S., Gunji, T., Hanhart, C., Harada, M., Harada, T., Hayakawa, S., He, B. R., Hiyama, E., Honda, R., Ichikawa, Y., Isaka, M., Jido, D., Jinno, A., Kamada, K., Kamiya, Y., Kong, Y. K., Liu, Z. W., Lu, J. X., Miwa, K., Mizutani, K., Murakami, K., Muto, R., Murase, K., Nagao, S., Nanamura, T., Nanjo, H., Nara, Y., Ohnishi, A., Qiu, J. W., Sakaguchi, A., Sakuma, F., Santopinto, E., Scordo, A., Sekihara, T., Seong, C., Shevchenko, N. V., Stone, J. R., Strakovsky, I., Suzuki, K., Takahashi, H., Takizawa, M., Tamura, H., Tomida, N., Umeya, A., Doce, O. Vázquez, Yamagata-Sekihara, J., Yamamoto, T. O., Xiao, Y., Yin, Z., Yu, Z., Zou, B. S.
The mini proceedings of the "Fourth International Workshop on the Extension Project for the J-PARC Hadron Experimental Facility (HEF-ex 2024) [https://kds.kek.jp/event/46965]" held at J-PARC, February 19-21, 2024, are presented. The workshop was devo
Externí odkaz:
http://arxiv.org/abs/2409.00366
Autor:
Baudis, L., Biondi, R., Bismark, A., Clozza, A., Curceanu, C., Galloway, M., Napolitano, F., Piastra, F., Piscicchia, K., Porcelli, A., García, D. Ramírez
The Pauli Exclusion Principle (PEP) appears from fundamental symmetries in quantum field theories, but its physical origin is still to be understood. High-precision experimental searches for small PEP violations permit testing key assumptions of the
Externí odkaz:
http://arxiv.org/abs/2408.02500
Autor:
Dadgar, M., Parzych, S., Ardebili, F. Tayefi, Baran, J., Chug, N., Curceanu, C., Czerwinski, E., Dulski, K., Eliyan, K., Gajos, A., Hiesmayr, B. C., Kacprzak, K., Kaplon, L., Klimaszewski, K., Konieczka, P., Korcyl, G., Kozik, T., Krzemien, W., Kumar, D., Niedzwiecki, S., Panek, D., del Rio, E. Perez, Raczynski, L., Sharma, S., Shivani, Shopa, R. Y., Skurzok, M., Ardebili, K. Tayefi, Vandenberghe, S., Wislicki, W., Stepien, E., Moskal, P.
The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring,
Externí odkaz:
http://arxiv.org/abs/2408.00574
Autor:
Kaplon, L., Baran, J., Chug, N., Coussat, A., Curceanu, C., Czerwinski, E., Dadgar, M., Dulski, K., Gajewski, J., Gajos, A., Hiesmayr, B., Valsan, E. Kavya, Klimaszewski, K., Korcyl, G., Kozik, T., Krzemien, W., Kumar, D., Moskal, G., Niedzwiecki, S., Panek, D., Parzych, S., del Rio, E. Perez, Raczynski, L., Rucinski, A., Sharma, S., Shivani, S., Shopa, R., Silarski, M., Skurzok, M., Stepien, E., Ardebili, F. Tayefi, Ardebili, K. Tayefi, Wislicki, W., Moskal, P.
Publikováno v:
Nuclear Inst. and Methods in Physics Research, A 1051 (2023) 168186
Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of lon
Externí odkaz:
http://arxiv.org/abs/2407.19465
Autor:
Moskal, P., Kumar, D., Sharma, S., Beyene, E. Y., Chug, N., Coussat, A., Curceanu, C., Czerwinski, E., Das, M., Dulski, K., Gorgol, M., Jasinska, B., Kacprzak, K., Kaplanoglu, T., Kaplon, L., Klimaszewski, K., Kozik, T., Lisowski, E., Lisowski, F., Mryka, W., Niedzwiecki, S., Parzych, S., del Rio, E. P., Raczynski, L., Radler, M., Shopa, R. Y., Skurzok, M., Stepien, E. L., Tanty, P., Ardebili, K. Tayefi, Eliyan, K. Valsan, Wislicki, W.
In the state-of-the-art Positron Emission Tomography (PET), information about the polarization of annihilation photons is not available. Current PET systems track molecules labeled with positron-emitting radioisotopes by detecting the propagation dir
Externí odkaz:
http://arxiv.org/abs/2407.08574
Autor:
Bosnar, D., Abbene, L., Amsler, C., Artibani, F., Bazzi, M., Bragadireanu, M., Buttacavoli, A., Cargnelli, M., Carminati, M., Clozza, A., Clozza, F., Deda, G., De Paolis, L., Del Grande, R., Dulski, K., Fabbietti, L., Fiorini, C., Friščić, I., Guaraldo, C., Iliescu, M., Iwasaki, M., Khreptak, A., Makek, M., Manti, S., Marton, J., Moskal, P., Napolitano, F., Niedźwiecki, S., Ohnishi, H., Piscicchia, K., Scordo, A., Sgaramella, F., Sirghi, D., Sirghi, F., Skurzok, M., Silarski, M., Spallone, A., Toho, K., Tüchler, M., Doce, O. Vasquez, Zmeskal, J., Curceanu, C.
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$\Phi$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati
Externí odkaz:
http://arxiv.org/abs/2405.12942