Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Cristina I.C. Silvestre"'
Publikováno v:
Analytica Chimica Acta. 699:193-197
A novel flow method for the determination of chemical oxygen demand (COD) is proposed in this work. It relies on the combination of a fully automated single interface flow system, an on-line UV photocatalytic unit and quantum dot (QD) nanotechnology.
Autor:
João L.M. Santos, Cristina I.C. Silvestre, Elias A.G. Zagatto, Christian Frigerio, José L. F. C. Lima, Paula R. Fortes
Publikováno v:
Talanta. 84:1314-1317
A fully automated multipumping flow system (MPFS) using water-soluble CdTe quantum dots (QD) as sensitizers is proposed for the chemiluminometric determination of the anti-diabetic drugs gliclazide and glipizide in pharmaceutical formulations. The na
Autor:
José L. F. C. Lima, Paula C.A.G. Pinto, M. Lúcia M.F.S. Saraiva, Cristina I.C. Silvestre, Marcela A. Segundo
Publikováno v:
Analytica Chimica Acta. 689:160-177
Sequential injection analysis systems have been extensively exploited in the last decades for the implementation of enzyme based assays aiming the evaluation of enzyme activity or the determination of specific analytes. The most prominent aspects of
Autor:
João L.M. Santos, Elias A.G. Zagatto, S.N. Rodrigues, José L. F. C. Lima, Cristina I.C. Silvestre
Publikováno v:
Talanta. 81:1847-1851
The exploitation of aqueous biphasic extraction is proposed for the first time in flow analysis. This extraction strategy stands out for being environmentally attractive since it is based in the utilization of two immiscible phases that are intrinsic
Autor:
Elias A.G. Zagatto, José L. F. C. Lima, Mário A. Feres, Cristina I.C. Silvestre, João L.M. Santos
Publikováno v:
Microchemical Journal. 94:60-64
Single interface flow systems (SIFA) present some noteworthy advantages when compared to other flow systems, such as a simpler configuration, a more straightforward operation and control and an undemanding optimisation routine. Moreover, the plain re
Publikováno v:
Spectroscopy Letters. 42:341-350
Two automatic sequential injection analysis methodologies were developed for the enzymatic determination of allopurinol in pharmaceutical formulations. Both methodologies were based on the inhibition by allopurinol of the reaction catalysed by xanthi
Publikováno v:
Talanta. 77:518-521
A single reaction interface flow analysis (SIFA) system for the monitoring of mannitol in pharmaceutical formulations and human urine is presented. The developed approach takes advantage of the mannitol scavenger aptitude to inhibit the chemiluminesc
Publikováno v:
Analytica chimica acta. 652(1-2)
Liquid-liquid extractions (LLE) are a common sample pre-treatment in many analytical applications. This review aims at providing a critical overview of the distinct automated continuous flow-based approaches that were developed for liquid-liquid extr
Publikováno v:
Talanta. 79(4)
A fully automated methodology was developed for the determination of the thyroid hormones levothyroxine (T4) and liothyronine (T3). The proposed method exploits the formation of highly coloured charge-transfer (CT) complexes between these compounds,