Zobrazeno 1 - 10
of 245
pro vyhledávání: '"Conforti, S"'
Ultraluminous X-ray sources (ULXs) are enigmatic sources first discovered in the 1980s in external galaxies. They are characterized by their extraordinarily high X-ray luminosity, which often exceeds $10^{40}\, \rm{erg \; s^{-1}}$. Our study aims to
Externí odkaz:
http://arxiv.org/abs/2411.13659
Autor:
Agapopoulou, C., Beresford, L. A., Boumediene, D. E., García, L. Castillo, Conforti, S., de la Taille, C., Corpe, L. D., de Sousa, M. J. Da Cunha Sargedas, Dinaucourt, P., Falou, A., Gautam, V., Gong, D., Grieco, C., Grinstein, S., Guindon, S., Howard, A., Kurdysh, O., Kuwertz, E., Li, C., Makovec, N., Markovic, B., Martin-Chassal, G., Mazzini, R., Milke, C., Morenas, M., Perrin, O., Raskina, V., Rizzi, C., Ruckman, L., Rummler, A., Sacerdoti, S., Saito, G., Seguin-Moreau, N., Serin, L., Yang, X., Ye, J., Zhou, W.
This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad
Externí odkaz:
http://arxiv.org/abs/2306.08949
Autor:
Aimard, B., Aizawa, L., Alt, C., Asaadi, J., Auger, M., Aushev, V., Autiero, D., Balaceanu, A., Balik, G., Balleyguier, L., Bechetoille, E., Belver, D., Blebea-Apostu, A. M., Bolognesi, S., Bordoni, S., Bourgeois, N., Bourguille, B., Bremer, J., Brown, G., Brunetti, G., Brunetti, L., Caiulo, D., Calin, M., Calvo, E., Campanelli, M., Cankocak, K., Cantini, C., Carlus, B., Cautisanu, B. M., Chalifour, M., Chappuis, A., Charitonidis, N., Chatterjee, A., Chiriacescuf, A., Chiu, P., Conforti, S., Cotte, P., Crivelli, P., Cuesta, C., Dawson, J., De Bonis, I., De La Taille, C., Delbart, A., Di Luise, S., Doizon, F., Drancourt, C., Duchesneau, D., Dulucq, F., Duval, F., Emery, S., Ereditato, A., Falcone, A., Fusshoeller, K., Gallego-Ros, A., Galymov, V., Geffroy, N., Gendotti, A., Gherghel-Lascu, A., Gil-Botella, I., Girerd, C., Gomoiu, M. C., Gorodetzky, P., Hamada, E., Hanni, R., Hasegawa, T., Holin, A., Horikawa, S., Ikeno, M., Jiménez, S., Jipa, A., Karolak, M., Karyotakis, Y., Kasai, S., Kasami, K., Kishishita, T., Konari, H., Kreslo, I., Kryn, D., Kunzé, P., Kurokawa, M., Kuromori, Y., Lastoria, C., Lazanu, I., Lehmann-Miotto, G., Leyton, M., Lira, N., Loo, K., Lorca, D., Lutz, P., Lux, T., Maalampi, J., Maire, G., Maki, M., Manenti, L., Margineanu, R. M., Marteau, J., Martin-Chassard, G., Mathez, H., Mazzucato, E., Misitano, G., Mladenov, D., Bueno, L. Molina, Mosu, T. S., Mu, W., Murphy, S., Nakayoshi, K., Narita, S., Navas-Nicolás, D., Negishi, K., Nessi, M., Niculescu-Oglinzanu, M., Noto, F., Noury, A., Onishchuk, Y., Palomares, C., Parvu, M., Patzak, T., Penichot, Y., Pennacchio, E., Periale, L., Pessard, H., Pietropaolo, F., Pugnere, D., Radics, B., Redondo, D., Regenfus, C., Remoto, A., Resnati, F., Ristea, O., Rubbia, A., Saftoiu, A., Sakashita, K., Sanchez, F., Santos, C., Scarpelli, A., Schloesser, C., Sendai, K., Sergiampietri, F., Shahsavarani, S., Shoji, M., Sinclair, J., Soto-Oton, J., Stanca, D. I., Stefan, D., Sulej, R., Tanaka, M., Toboaru, V., Tonazzo, A., Tromeur, W., Trzaska, W. H., Uchida, T., Urda, L., Vannucci, F., Vasseur, G., Verdugo, A., Viant, T., Vihonen, S., Vilalte, S., Weber, M., Wu, S., Yu, J., Zambelli, L., Zito, M.
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The perform
Externí odkaz:
http://arxiv.org/abs/2010.08370
Autor:
Aimard, B., Alt, Ch., Asaadi, J., Auger, M., Aushev, V., Autiero, D., Badoi, M. M., Balaceanu, A., Balik, G., Balleyguier, L., Bechetoille, E., Belver, D., Blebea-Apostu, A. M., Bolognesi, S., Bordoni, S., Bourgeois, N., Bourguille, B., Bremer, J., Brown, G., Brunetti, G., Brunetti, L., Caiulo, D., Calin, M., Calvo, E., Campanelli, M., Cankocak, K., Cantini, C., Carlus, B., Cautisanu, B. M., Chalifour, M., Chappuis, A., Charitonidis, N., Chatterjee, A., Chiriacescu, A., Chiu, P., Conforti, S., Cotte, P., Crivelli, P., Cuesta, C., Dawson, J., De Bonis, I., De La Taille, C., Delbart, A., Desforge, D., Di Luise, S., Dimitru, B. S., Doizon, F., Drancourt, C., Duchesneau, D., Dulucq, F., Dumarchez, J., Duval, F., Emery, S., Ereditato, A., Esanu, T., Falcone, A., Fusshoeller, K., Gallego-Ros, A., Galymov, V., Geroy, N., Gendotti, A., Gherghel-Lascu, M., Giganti, C., Gil-Botella, I., Girerd, C., Gomoiu, M. C., Gorodetzky, P., Hamada, E., Hanni, R., Hasegawa, T., Holin, A., Horikawa, S., Ikeno, M., Jimenez, S., Jipa, A., Karolak, M., Karyotakis, Y., Kasai, S., Kasami, K., Kishishita, T., Kreslo, I., Kryn, D., Lastoria, C., Lazanu, I., Lehmann-Miotto, G., Lira, N., Loo, K., Lorca, D., Lutz, P., Lux, T., Maalampi, J., Maire, G., Maki, M., Manenti, L., Margineanu, R. M., Marteau, J., Martin-Chassard, G., Mathez, H., Mazzucato, E., Misitano, G., Mitrica, B., Mladenov, D., Bueno, L. Molina, Martinez, C. Moreno, Mols, J. P., Mosu, T. S., Mug, W., Munteanu, A., Murphy, S., Nakayoshi, K., Narita, S., Navas-Nicolas, D., Negishi, K., Nessi, M., Niculescu-Oglinzanu, M., Nita, L., Noto, F., Noury, A., Onishchuk, Y., Palomares, C., Parvu, M., Patzak, T., Penichot, Y., Pennacchio, E., Periale, L., Pessard, H., Pietropaolo, F., Piret, Y., Popov, B., Pugnere, D., Radics, B., Redondo, D., Regenfus, C., Remoto, A., Resnati, F., Rigaut, Y. A., Ristea, C., Rubbia, A., Saftoiu, A., Sakashita, K., Sanchez, F., Santos, C., Scarpelli, A., Schloesser, C., Lavina, L. Scotto, Sendai, K., Sergiampietri, F., Shahsavarani, S., Shoji, M., Sinclair, J., Soto-Oton, J., Stanca, D. L., Stefan, D., Stroescu, P., Sulej, R., Tanaka, M., Toboaru, V., Tonazzo, A., Tromeur, W., Trzaska, W. H., Uchida, T., Vannucci, F., Vasseur, G., Verdugo, A., Viant, T., Vihonen, S., Vilalte, S., Weber, M., Wu, S., Yu, J., Zambelli, L., Zito, M.
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers se
Externí odkaz:
http://arxiv.org/abs/1806.03317
Autor:
Ahmad, S., Blin, S., Callier, S., Cizel, J.B., Conforti, S., de La Taille, C., Dulucq, F., Fleury, J., Martin-Chassard, G., Raux, L., Seguin-Moreau, N., Thienpont, D.
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A 11 January 2021 986
PMm2: large photomultipliers and innovative electronics for the next-generation neutrino experiments
Autor:
Genolini, B., Barrillon, P., Blin, S., Campagne, J. -E., Combettes, B., Conforti, S., De-haine, A. -G., Duchesneau, D., Dulucq, F., Dumont-Dayot, N., Favier, J., Fouché, F., Hermel, R., de La Taille, C., Martin-Chassard, G., Trung, T. Nguyen, Périnet, C., Peyré, J., Pouthas, J., Raux, L., Rindel, E., Rosier, P., Tassan-Viol, J., Wei, W., Zghiche, A.
Publikováno v:
Nucl.Instrum.Meth.A610:249-252,2009
The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large
Externí odkaz:
http://arxiv.org/abs/0811.2681
Autor:
Casado, M.P., Adam Bourdarios, C., Belfkir, M., Berger, N., Costanza, F., Cueto, A., Delmastro, M., Di Ciaccio, L., Franco, L., Goy, C., Guillemin, T., Hryn’ova, T., Jézéquel, S., Koletsou, I., Lafaye, R., Levêque, J., Lorenzo Martinez, N., Portales, L., Sauvan, E., Wingerter-Seez, I., Agaras, M.N., Barbe, W.M., Boumediene, D., Calvet, D., Calvet, S., Donini, J., Jimenez Morales, F.A., Jouve, F., Lambert, D., Madar, R., Manen, S., Megy, T., Nibigira, E., Royer, L., Rustige, L., Santoni, C., Soulier, A., Vandaele, R., Vazeille, F., Collot, J., Crépé-Renaudin, S., Delsart, P.A., Genest, M.H., Hulsken, R., Kuna, M., Lleres, A., Lucotte, A., Malek, F., Portillo Quintero, D.M., Stark, J., Trocmé, B., Agapopoulou, C., Al Khoury, K., Atmani, H., Bassalat, A., Blot, A., Bonis, J., de Vivie De Regie, J.B., Delgove, D., Delporte, C., Duflot, L., Escalier, M., Falou, A.C., Fayard, L., Fournier, D., Ghosh, A., Grivaz, J.-F., Guerguichon, A., Hohov, D., Hrivnac, J., Iconomidou-Fayard, L., Kotsokechagia, A., Lounis, A., Makovec, N., Migayron, A., Morange, N., Perego, M.M., Petroff, P., Puzo, P., Rousseau, D., Rybkin, G., Sacerdoti, S., Schaffer, A.C., Serin, L., Simion, S., Tanaka, R., Trofymov, A., Varouchas, D., Zerwas, D., Zhang, Z., Rahal, G., Aad, G., Barbero, M., Bartolini, G., Calvet, T.P., Coadou, Y., Diaconu, C., Djama, F., Duperrin, A., Feligioni, L., Fortin, E., Guo, Z., Hallewell, G.D., Hubaut, F., Knoops, E.B.F.G., Guirriec, E. Le, Monnier, E., Muanza, S., Nagy, E., Nguyen, H.D.N., Petit, E., Pralavorio, P., Rozanov, A., Strebler, T., Talby, M., Tisserant, S., Toth, J., Vu, N.K., Conforti, S., de La Taille, C., Dinaucourt, P., Martin-Chassard, G., Seguin-Moreau, N., Beau, T., Bernardi, G., Bomben, M., Calderini, G., Camacho Toro, R., Crescioli, F., Derue, F., Hankache, R., Krasny, M.W., Lacour, D., Laforge, B., Laporte, D., Leopold, A., Luise, I., Malaescu, B., Marchiori, G., Nikolic-Audit, I., Nomidis, I., Ocariz, J., Pascual Dominguez, L., Poggioli, L., Ridel, M., Roos, L., Trincaz-Duvoid, S., Zahreddine, J., Andari, N., Bachacou, H., Balli, F., Bauer, F., Besson, N., Boonekamp, M., Chevalérias, T.J.A., Chevalier, L., Deliot, F., Formica, A., Giraud, P.F., Guyot, C., Hassani, S., Jeanneau, F., Kawamoto, T., Khandoga, M., Kolb, M., Laporte, J.F., Mansoulie, B., Meyer, J-P., Moskalets, T., Nicolaidou, R., Ouraou, A., Peyaud, A., Schoeffel, L., Schune, Ph., Schwemling, Ph., Vandenbroucke, M., Xu, T.
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022, 1032, pp.166628. ⟨10.1016/j.nima.2022.166628⟩
Dipòsit Digital de Documents de la UAB
Universitat Autònoma de Barcelona
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022, 1032, pp.166628. ⟨10.1016/j.nima.2022.166628⟩
Dipòsit Digital de Documents de la UAB
Universitat Autònoma de Barcelona
The increase of the particle flux (pile-up) at the HL-LHC with instantaneous luminosities up to L = 7.5 $\times$ 10 $^{34}$ cm $^{-2}$ s $^{-1}$ will have a severe impact on the ATLAS detector reconstruction and trigger performance. The end-cap and f
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f225fe1a316a882bd58d2a3e53a87fd6
https://hal.science/hal-03978531/document
https://hal.science/hal-03978531/document
Autor:
Fabbiani M., Lombardi A., Colaneri M., Del Poggio P., Perini P., D'Ambrosio R., Degasperi E., Dibenedetto C., Giorgini A., Pasulo L., Maggiolo F., Castelli F., Brambilla P., Spinelli O., Re T., Lleo A., Rumi M., Uberti-Foppa C., Soria A., Aghemo A., Lampertico P., Baiguera C., Schiavini M., Fagiuoli S., Bruno R., Borghi M., Soffredini R., Perbellini R., Gori A., Ferroni V., Colpani M., Manini M., Cologni G., Lazzaroni S., Vinci M., De Nicola S., Mazzarelli C., Angelini Zucchetti T., Picciotto V., Puoti M., Rossotti R., Landonio S., Magni C. F., Rizzardini G., Colella E., Columpsi P., Gambaro A., Spolti A., Magnani C., Vigano P., Mena M., Villa M., Caramma I., Basilico C., Capelli F., Biagiotti S., Mazzone A., Saladino V., Baldacci M. P., Gatti F., Varalli L., Morini L., Menzaghi B., Farinazzo M., Meli R., Plaz Torres M. C., Fanetti I., Orellana D., Zermiani P., Zuin M., De Bona A., D'Arminio Monforte A., Capretti A., Taddei M. T., Soncini M., Spinetti A., Zaltron S., Pigozzi M. G., Rossini A., Pan A., Dal Zoppo S., Zoncada A., Memoli M., Salpietro S., Hamid H., Messina E., Colombo A. E., Giglio O., Bonfanti P., Molteni C., Terreni N., Spinzi G., Conforti S., Clerici E., Menozzi F., Buscarini E., Centenaro R., Corbellini A., Noventa F., Gritti S., Giani P.
In routine clinical practice, hepatitis C virus-infected patients can prematurely discontinue the prescribed regimen for several reasons. The aim of our study was to investigate sustained virological response (SVR12) rates in patients who prematurely
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6778077543a3057e31157aaac3ad45f5
http://hdl.handle.net/11379/536940
http://hdl.handle.net/11379/536940
Autor:
Wa105 Collaboration T., Aimard B., Aizawa L., Alt C., Asaadi J., Auger M., Aushev V., Autiero D., Balaceanu A., Balik G., Balleyguier L., Bechetoille E., Belver D., Blebea-Apostu A. M., Bolognesi S., Bordoni S., Bourgeois N., Bourguille B., Bremer J., Brown G., Brunetti L., Brunetti G., Caiulo D., Calin M., Calvo E., Campanelli M., Cankocak K., Cantini C., Carlus B., Cautisanu B. M., Chalifour M., Chappuis A., Charitonidis N., Chatterjee A., Chiriacescuf A., Chiu P., Coan T., Conforti S., Cotte P., Crivelli P., Cuesta C., Dawson J., De Bonis I., De La Taille C., Delbart A., Di Luise S., Doizon F., Drancourt C., Duchesneau D., Dulucq F., Duval F., Emery S., Ereditato A., Falcone A., Fusshoeller K., Gallego-Ros A., Galymov V., Geffroy N., Gendotti A., Gherghel-Lascu A., Gil-Botella I., Girerd C., Gomoiu M. C., Gorodetzky P., Hamada E., Hanni R., Hasegawa T., Holin A., Horikawa S., Ikeno M., Jimenez S., Jipa A., Karolak M., Karyotakis Y., Kasai S., Kasami K., Kishishita T., Konari H., Kreslo I., Kryn D., Kunze P., Kurokawa M., Kuromori Y., Lastoria C., Lazanu I., Lehmann-Miotto G., Leyton M., Lira N., Liubarska M., Loo K., Lorca D., Lutz P., Lux T., Maalampi J., Maire G., Maki M., Manenti L., Margineanu R. M., Marteau J., Martin-Chassard G., Mathez H., Mazzucato E., Misitano G., Mladenov D., Molina Bueno L., Mosu T. S., Mu W., Murphy S., Nakayoshi K., Narita S., Navas-Nicolas D., Negishi K., Nessi M., Niculescu-Oglinzanu M., Noto F., Noury A., Onishchuk Y., Palomares C., Parvu M., Patzak T., Penichot Y., Pennacchio E., Periale L., Pessard H., Pietropaolo F., Pugnere D., Radics B., Redondo D., Regenfus C., Remoto A., Resnati F., Ristea O., Rubbia A., Saftoiu A., Sakashita K., Sanchez F., Santos C., Scarpelli A., Schloesser C., Sendai K., Sergiampietri F., Shahsavarani S., Shoji M., Sinclair J., Soto-Oton J., Stanca D. I., Stefan D., Sulej R., Tanaka M., Toboaru V., Tonazzo A., Tromeur W., Trzaska W. H., Uchida T., Urda L., Vannucci F., Vasseur G., Verdugo A., Viant T., Vihonen S., Vilalte S., Weber M., Wu S., Yu J., Zambelli L., Zito M.
Publikováno v:
JINST
JINST, 2021, 16 (08), pp.P08063. ⟨10.1088/1748-0221/16/08/P08063⟩
Journal of Instrumentation
Digibug. Repositorio Institucional de la Universidad de Granada
instname
JINST, 2021, 16 (08), pp.P08063. ⟨10.1088/1748-0221/16/08/P08063⟩
Journal of Instrumentation
Digibug. Repositorio Institucional de la Universidad de Granada
instname
This work would not have been possible without the support of the Swiss National Science Foundation, Switzerland; CEA and CNRS/IN2P3, France; KEK and the JSPS program, Japan; Ministerio de Ciencia e Innovacion in Spain under grants FPA2016-77347-C2,
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4448b1e4d8b5693628dd101e8d196752
https://hal.archives-ouvertes.fr/hal-03217550
https://hal.archives-ouvertes.fr/hal-03217550
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A 1 November 2010 623(1):492-494