Zobrazeno 1 - 10
of 1 230
pro vyhledávání: '"Computer Automated Measurement and Control"'
Publikováno v:
American Journal of Physics. 88:70-80
There is a new generation of high-speed programmable pulse digitizers available now from several vendors at modest cost. These digitizers in tandem with on-board or post-processing software combine to produce a Software-Defined Electronics (SDE) syst
Autor:
Stanislaw Kistryn
Publikováno v:
Advanced Knowledge Application in Practice
In a vast area of fundamental nuclear/particle physics investigations are performed with relatively simple setups, encompassing up to few thousands of analog data sources. Multiplicity for events in such experiments is usually of the order of few ten
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e25ad7d4680bf795465052d3b441141f
http://www.intechopen.com/articles/show/title/readout-system-for-medium-size-experiments
http://www.intechopen.com/articles/show/title/readout-system-for-medium-size-experiments
Autor:
Sumita Bhattacharyya, R. Banik, G. Mukherjee, S. Imran, A. K. Sinha, S. Samanta, Ratnajit Bhattacharjee, S. S. Ghugre, Soumik Bhattacharya, R. Palit, R. Raut, H. Tan, Anindya Goswami, K. Basu, S. K. Das
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 893:138-145
The development of a digitizer based pulse processing and data acquisition system for γ -ray spectroscopy with large detector arrays is presented. The system is based on 250 MHz 12-bit digitizers, and is triggered by a user chosen multiplicity of Co
Publikováno v:
Applied Radiation and Isotopes. 119:101-104
The 117mSn isotope was produced via fast, 14.1MeV neutron activation of natural tin and studied with a background shielded HPGe detector. To enable time-resolved γ-ray spectroscopy to precisely measure the half-life of 117mSn, a commercial DAQ was r
Publikováno v:
Physics of Particles and Nuclei Letters. 14:160-167
The eight-channel high-voltage power supply system based on using the Wenzel Elektronik N1130 module is described. The characteristics of 8DAC-12 and 8ADC-14 types control modules of CAMAC standard designed for high-voltage systems are presented. Thi
Publikováno v:
Fusion Engineering and Design. 112:860-864
The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And C
Publikováno v:
Fusion Engineering and Design. 112:872-876
The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), w
Autor:
Sanjay Kumar Sharma
Publikováno v:
IOSR Journal of Electronics and Communication Engineering. 11:28-36
Delays are used in a variety of ways in Nuclear and High Energy Physics experiments which often deal with a large number of detectors. These detectors give out analog signals depicting several parameters like pulse height, width, time of arrival, pul
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 371:148-152
With the recent advances towards modern Ion Beam Analysis (IBA), going from one- or few-parameter detector systems to multi-parameter systems, it has been necessary to expand and replace the more than twenty years old CAMAC based system. A new VME mu
Publikováno v:
VESTNIK of Samara University. Aerospace and Mechanical Engineering. 14:211-222
The results of the analysis of design and development of data measuring systems of oceanographic parameters in the 60-70s and 80-90s are presented in the paper. Data measuring systems based on the CAMAC standard (created under the leadership of acade