Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Colin D. Schauder"'
Publikováno v:
IEEE Transactions on Power Delivery. 14:1115-1123
The interline power flow controller (IPFC) proposed is a new concept for the compensation and effective power flow management of multi-line transmission systems. In its general form, the IPFC employs a number of inverters with a common DC link, each
Autor:
A.-A. Edris, A.S. Mehraban, Laszlo Gyugyi, E.J. Stacey, Colin D. Schauder, B.A. Renz, A.J.F. Keri, L. Kovalsky
Publikováno v:
IEEE Transactions on Power Delivery. 14:1374-1381
The installation of the world's first unified power flow controller (UPFC) has been completed and a series of commissioning tests were conducted at the Inez Substation of American Electric Power (AEP) in eastern Kentucky. The project is a collaborati
Autor:
A. Edris, T.R. Rietman, Laszlo Gyugyi, D.R. Torgerson, D.M. Hamai, Colin D. Schauder, M.R. Lund
Publikováno v:
IEEE Transactions on Power Delivery. 13:630-639
The UPFC is the most versatile and complex power electronic equipment that has emerged for the control and optimization of power flow in electrical power transmission systems. It offers major potential advantages for the static and dynamic operation
Autor:
E.J. Stacey, L. Kovalsky, M.R. Lund, A.J.F. Keri, A.S. Mehraban, A.-A. Edris, Laszlo Gyugyi, Colin D. Schauder
Publikováno v:
IEEE Transactions on Power Delivery. 13:1530-1535
American Electric Power (AEP) has selected its Inez Substation in eastern Kentucky for the location of the world's first Unified Power Flow Controller (UPFC) installation. Comprising two /spl plusmn/160 MVA voltage-sourced GTO-thyristor-based inverte
Autor:
A.-A. Edris, T.W. Cease, M. Gernhardt, Colin D. Schauder, T. Lemak, Laszlo Gyugyi, E.J. Stacey
Publikováno v:
IEEE Transactions on Power Delivery. 12:1805-1811
In 1995 a /spl plusmn/100 MVA static synchronous compensator (STATCON) was commissioned for the Tennessee Valley Authority (TVA) at the Sullivan substation in North-Eastern Tennessee, USA. This was an historic milestone in the initiative for flexible
Publikováno v:
IEEE Transactions on Power Delivery. 10:1486-1496
The availability of high power gate-turn-off (GTO) thyristors has led to the development of controllable reactive power sources, using electronic switching power converters, for use in power transmission systems. This new technology has resulted in e
Publikováno v:
IEEE Transactions on Power Delivery. 10:1085-1097
This paper shows that the unified power flow controller (UPFC) is able to control both the transmitted real power and, independently, the reactive power flows at the sending- and the receiving-end of the transmission line. The unique capabilities of
Autor:
C.L. Neft, Colin D. Schauder
Publikováno v:
IEEE Transactions on Industry Applications. 28:546-551
A description is given of the control strategy and hardware design for a 30-hp matrix converter (9-switch forced-commutation cycloconverter), which was developed for high-bandwidth four-quadrant-motor drive applications. The switching technique ensur
Autor:
Colin D. Schauder
Publikováno v:
Conference Record of the IEEE Industry Applications Society Annual Meeting.
A model-reference adaptive system (MRAS) for the estimation of induction motor speed from measured terminal voltages and currents is described. The estimated speed is used as feedback in a vector control system, thus achieving moderate bandwidth spee
Autor:
Colin D. Schauder
Publikováno v:
Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.
A regenerative two-quadrant power converter which is suitable for interfacing between the AC mains and the DC link of a voltage source inverter is described. The circuit provides highly reliable commutation in the regeneration mode using only a singl