Zobrazeno 1 - 10
of 86
pro vyhledávání: '"Clarence P. Cain"'
Autor:
David J. Stolarski, Duane Cox, Michelle L. Imholte, Carrie C. Crane, Benjamin A. Rockwell, Mary F. Cooper, Gary D. Noojin, Clarence P. Cain, Semih S. Kumru
Publikováno v:
Lasers in Surgery and Medicine. 37:59-63
BACKGROUND AND OBJECTIVES Terawatt (TW) lasers have become commonplace since the development of the chirped-pulse amplification method using Ti:sapphire and Nd:glass laser rods. We have measured the minimum visible lesion (MVL) thresholds for porcine
Autor:
Benjamin A. Rockwell, David J. Stolarski, Rebecca T. Hall, Gary D. Noojin, Robert J. Thomas, Cynthia A. Toth, Clarence P. Cain
Publikováno v:
Lasers in Surgery and Medicine. 31:9-17
Background and Objectives In order to provide a direct comparison of the effects of mode-locked systems to those with continuous-wave (CW) or nonpulsed output, we have performed an experiment with lasers possessing otherwise identical output characte
Autor:
David J. Stolarski, Clarence P. Cain, Robert J. Thomas, Gary D. Noojin, Benjamin A. Rockwell, Cynthia A. Toth
Publikováno v:
Health Physics. 82:855-862
Multiple-pulse lasers are routinely used in the laboratory for research, manufacturing, medical procedures, and in military applications. In order to provide a safe work environment for personnel using these lasers, safety standards have been establi
Autor:
David J. Stolarski, Paul K. Kennedy, Clarence P. Cain, Benjamin A. Rockwell, Cheryl Dawn DiCarlo, Daniel X. Hammer, Gary D. Noojin, William P. Roach, Cynthia A. Toth
Publikováno v:
Graefe's Archive for Clinical and Experimental Ophthalmology. 234:S28-S37
• Background: In vivo retinal injury studies using ultrashort-pulse lasers at visible wavelengths for both rabbit and primate eyes have shown that the degree of injury to the retina is not proportional to the pulse energy, especially at suprathresh
Autor:
Gordon T. Hengst, Paul K. Kennedy, Brent Eilert, Robert J. Thomas, Thomas R. Jost, Clarence P. Cain, Gary D. Noojin, Benjamin A. Rockwell, Dale J. Payne, David J. Stolarski, Richard A. Hopkins
Publikováno v:
Journal of biomedical optics. 4(3)
Laser damage threshold energies produced from ultrashort (i.e., ⩽1 ns) laser pulses are investigated as a function of both pulse width and spot size for an artificial retina. A piece of film acts as the absorbing layer and is positioned at the focu
Autor:
Andreas Schmitt-Sody, Gary D. Noojin, Adrian Lucero, William P. Roach, Clarence P. Cain, J. O'Loughlin
Publikováno v:
Conference on Lasers and Electro-Optics 2012.
We present new insights into laser filament coupling to a high AC electric field strength of 100kV/m. Previous studies showed a short delay time for filament coupling. Our observations indicate a large time delay between the plasma and the discharge
Autor:
Clarence P. Cain, Isaac D. Noojin, Harvey M. Hodnett, Robert J. Thomas, David J. Stolarski, Corey A. Harbert, Michael F. Foltz, Jeffrey W. Oliver, Kurt J. Schuster, Semih S. Kumru, Gavin D. Buffington, Gary D. Noojin, C. J. Finkeldei
Publikováno v:
Journal of biomedical optics. 15(6)
A series of experiments are conducted in vivo using Yucatan mini-pigs (Sus scrofa domestica) to determine thermal damage thresholds to the skin from 1940-nm continuous-wave thulium fiber laser irradiation. Experiments employ exposure durations from 1
Autor:
Cynthia A. Toth, Clarence P. Cain, M. E. Rogers, M. W. Mayo, Benjamin A. Rockwell, Gary D. Noojin, William P. Roach
Publikováno v:
Optics letters. 18(21)
We extend the application of the z-scan technique to determine the nonlinear refractive index (n(2)) for human and rabbit vitreous humor, water, and physiological saline. In these measurements there were nonlinear contributions to the measured signal
Autor:
Shana L. Phillips, Benjamin A. Rockwell, Richard A. Hopkins, David J. Stolarski, William P. Roach, Daniel X. Hammer, Brent Eilert, Dale J. Payne, Cynthia A. Toth, Jeffrey J. Druessel, Gary D. Noojin, Clarence P. Cain, Paul K. Kennedy, Rodney E. Amnotte
Publikováno v:
Journal of Laser Applications. 11:42-44
Recent studies of retinal damage due to ultrashort laser pulses have shown that less energy is required for retinal damage for pulses shorter than 1 ns than that for longer pulses. It has also been shown that more energy is required for near-infrared
Autor:
Justin J. Zohner, Benjamin A. Rockwell, David J. Stolarski, William P. Roach, Semih S. Kumru, Clarence P. Cain, Kevin Stockton, Gary D. Noojin
Publikováno v:
SPIE Proceedings.
In this paper we report on our combined measurements of the visible lesion thresholds for porcine skin for wavelengths in the infrared from 810 nm at 44 fs to 1318 nm at pulse durations of 50 ns and 350ms to 1540 nm including pulse durations of 31 ns