Zobrazeno 1 - 10
of 89
pro vyhledávání: '"Clare, Ford"'
Autor:
Aditi Kumar, Hafid O. Al-Hassi, Manushri Jain, Oliver Phipps, Clare Ford, Rousseau Gama, Helen Steed, Jeffrey Butterworth, John McLaughlin, Niall Galbraith, Matthew J. Brookes, Lauren E. Hughes
Publikováno v:
Scientific Reports, Vol 12, Iss 1, Pp 1-10 (2022)
Abstract This study examines the validity of measuring faecal bile acids (FBA) in a single stool sample as a diagnostic tool for bile acid diarrhoea (BAD) by direct comparison to the 75selenium-homotaurocholic acid (SeHCAT) scan. A prospective observ
Externí odkaz:
https://doaj.org/article/19d68fedaf0a4562a01e7e23152a03bb
Publikováno v:
Scientific Reports, Vol 12, Iss 1, Pp 1-14 (2022)
Abstract The objective of this study was to assess the diagnostic value of plasma neutrophil gelatinase-associated lipocalin (pNGAL) for the early diagnosis of acute kidney injury (AKI) in adult patients following cardiac surgery requiring cardiopulm
Externí odkaz:
https://doaj.org/article/90855fb9a9ff465bb360b6b88db723f1
Autor:
Sonika Sethi, Natasha Manuelpillai, Anandadeep Mandal, Olivia Simpson, Hana Morrissey, Patrick Ball, Hayley Sharrod-Cole, Clare Ford, Anna C. Whittaker, Mark Drayson, Adam Race, James Bateman, Supratik Basu, James Cotton
Publikováno v:
Brain, Behavior, & Immunity - Health, Vol 24, Iss , Pp 100492- (2022)
Objectives: To determine the seroprevalence of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) antibody status amongst healthcare workers (HCWs) working through the first wave of the Coronavirus (COVID-19) pandemic in 2020. To examine th
Externí odkaz:
https://doaj.org/article/f8423f6fcf7741af97a9d5cb4b436f07
Publikováno v:
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 60:92-99
Background The widely accepted practice of not reporting any results from ethylenediaminetetraacetic acid (EDTA) contaminated samples necessitates repeat phlebotomy and could delay clinical management decisions. EDTA, however, interferes variably or
Publikováno v:
Clinical Biochemistry. 103:25-28
Manufacturer-provided assay-specific reference intervals may not compensate for between assay differences leading to method related clinical discordance. Not all laboratories, however, assess clinical concordance as part of method comparison studies.
Publikováno v:
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 58:638-645
Background A large discordance in the diagnosis and potential management of hypothyroidism using Abbott and Roche thyroid assays has been reported recently. The difference in Abbott and Roche thyroid-stimulating hormone (TSH) results in these studies
Publikováno v:
Annals of clinical biochemistry.
Background Ethylenediaminetetraacetic acid (EDTA) contamination of serum samples is common but under-recognized unless EDTA is measured. Incorrect order of draw with closed phlebotomy (vacutainer) does not cause EDTA contamination. EDTA contamination
Autor:
Michael Udegbune, Hayley Sharrod–Cole, Sarah Townsend, Ben Allen, Matthew J Brookes, Clare Ford, Rousseau Gama
Publikováno v:
Annals of clinical biochemistry. 59(6)
There are limited and conflicting data on the value of serum calprotectin (sCp) in discriminating active from inactive disease activity in ulcerative colitis (UC). Faecal calprotectin (fCp), sCp, serum C-reactive protein (sCRP) and platelets were com
Autor:
Tejas Kalaria, Jonathan Fenn, Anna Sanders, Alexandra Yates, Christopher Duff, Helen Ashby, Pervaz Mohammed, Clare Ford, Rousseau Gama
Publikováno v:
Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme. 54(7)
We assessed the impact of intact parathyroid hormone (iPTH) and adjusted calcium analyses on Abbott, Roche and Siemens analytical platforms in the diagnosis of normocalcaemic primary hyperparathyroidism (NCPHPT). These assays are used by over 85% of
Autor:
Jonathan Fenn, Pervaz Mohammed, Harit Buch, Clare Ford, Anna Sanders, Tejas Kalaria, Helen L Ashby, Rousseau Gama
Publikováno v:
Clinical Endocrinology. 94:1012-1016
We assessed the commutativity of Roche and Abbott thyroid assays in the diagnosis and management of subclinical hypothyroidism (SCH). The Roche and Abbott thyroid assays are used by approximately 75% of clinical laboratories in the UK.Consecutive sam