Publikováno v:
The Journal of Chemical Thermodynamics. 41:689-694
A vapour phase flow mixing calorimeter has been used to measure the heat of mixing H m E of (0.5H2O + 0.5O2)(g) and (0.5H2O + 0.5N2)(g) at the pressure p = 0.101325 MPa and at temperatures from (373.15 to 493.15) K. The H m E measurements were analys
Autor:
Christopher J. Wormald
Publikováno v:
The Journal of Chemical Thermodynamics. 35:1019-1030
A flow mixing calorimeter has been used to measure the excess molar enthalpy HmE of gaseous (water + hydrogen sulphide) at the mole fraction y=0.5, at standard atmospheric pressure, and over the temperature range 383.15 K to 483.15 K. Information abo
Autor:
Christopher J. Wormald, A.P. du’Gay
Publikováno v:
The Journal of Chemical Thermodynamics. 35:393-403
A flow mixing calorimeter followed by a vibrating-tube densimeter has been used to measure excess molar enthalpies H m E and excess molar volumes V m E of { x C 4 H 10 +(1− x )SF 6 }. Measurements over a range of mole fractions x have been made in
Autor:
R.W. Hodgetts, Christopher J. Wormald
Publikováno v:
Fluid Phase Equilibria. 204:303-308
Flow calorimetric measurements of the excess molar enthalpy HmE of {xCO2+(1−x)CS2} made in the liquid region are described. The measurements were made at the pressure p=5.0 MPa and the temperatures T=250.15 and 270.15 K, and at the pressure p=7.5 M
Autor:
A.P du’Gay, Christopher J. Wormald
Publikováno v:
Fluid Phase Equilibria. 204:143-153
Measurements of the excess molar enthalpy HmE and the excess molar volume VmE of {xC4H10)+(1−x)SF6} made in the supercritical region at the pressure p=8.00 MPa and seven temperatures over the range 311.25–425.75 K are reported. The measurements e
Autor:
Christopher J. Wormald
Publikováno v:
The Journal of Chemical Thermodynamics. 35:91-100
A flow mixing calorimeter has been used to measure the excess molar enthalpy HmE of gaseous (water + sulphur dioxide) at the mole fraction y=0.5, at standard atmospheric pressure, and over the temperature range (383.2 to 483.2 K). Information about t
Autor:
Christopher J. Wormald, T.K Yerlett
Publikováno v:
The Journal of Chemical Thermodynamics. 34:1659-1669
Measurements of molar enthalpy increments for {0.5 H 2 O +0.5 ( CH 3 ) 2 CO } are reported. A counter-current water-cooled flow calorimeter was used to measure 113 enthalpy increments over the temperature range 373.2 K to 573.2 K at pressures from 0.
Autor:
B Wurzberger, Christopher J. Wormald
Publikováno v:
The Journal of Chemical Thermodynamics. 34:1567-1573
A flow mixing calorimeter has been used to measure the excess molar enthalpy HEm of gaseous (ammonia + carbon dioxide) at the mole fraction y=0.5, at standard atmospheric pressure, and over the temperature range 343.15 to 443.15 K. Second virial coef
Autor:
Christopher J. Wormald, A.P. du’Gay
Publikováno v:
The Journal of Chemical Thermodynamics. 34:1317-1327
A flow mixing calorimeter followed by a vibrating-tube densimeter has been used to measure excess molar enthalpies H m E and excess molar volumes V m E of { x C 3 H 8 + (1 − x )SF 6 } . Measurements over a range of mole fractions x have been made a
Autor:
Christopher J. Wormald, B Wurzberger
Publikováno v:
The Journal of Chemical Thermodynamics. 34:1279-1288
A flow mixing calorimeter has been used to measure the excess molar enthalpy H m E of gaseous (ammonia + benzene) and (ammonia + cyclohexane) at the mole fraction y = 0.5, at standard atmospheric pressure, and over the temperature range 363.15 K to 4