Publikováno v:
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
Large-volume 3D-position-sensitive CdZnTe is used in many applications for spectroscopy and Compton imaging. Being able to determine the incident gamma-ray flux, as a function of both the energy and direction, is, of course, a useful feature to provi
Forward Modeling Using Experimental Response Functions for High-Resolution CZT Imaging Spectrometers
Publikováno v:
2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
Large-volume 3D-position-sensitive CdZnTe is used in many applications. In many of these applications, it is useful to quickly predict what the spectral and image response will be to a particular source and environment. For instance, in scenario simu
Autor:
V. Velan, M. Horn, A.G. Singh, Blair Edwards, B. P. Tennyson, Ethan Bernard, N. Destefano, Christopher G. Wahl, Andreas Biekert, Moshe Gai, Q. Riffard, N. A. Larsen, Daniel McKinsey, E. M. Boulton, Sidney Cahn
Publikováno v:
Journal of Instrumentation. 15:P01023-P01023
Prompt scintillation signals from $^{83m}$Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because $^{83
Autor:
Timothy Slatina, Zhong He, Y. Andy Boucher, Jon Sowers, Steven Brown, Christopher G. Wahl, Jason M. Jaworski, Kevin Moran, Willy Kaye, Feng Zhang, Hao Yang
Publikováno v:
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).
Large-volume 3D-position-sensitive CZT offers several advantages for coded-aperture imaging, including high photoelectric fraction, sufficient depth to capture even high-energy gamma rays, and good energy resolution. Sub-pixel resolution can be used
Autor:
B. N. Edwards, Christopher G. Wahl, L. Tvrznikova, N. Destefano, N.A. Larsen, Ethan Bernard, Daniel McKinsey, B. P. Tennyson, E. M. Boulton, M. Horn, Moshe Gai
Publikováno v:
Journal of Instrumentation, vol 13, iss 01
Journal of Instrumentation, vol 13, iss 1
Edwards, BNV; Bernard, E; Boulton, EM; Destefano, N; Gai, M; Horn, M; et al.(2018). Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber. Journal of Instrumentation, 13(1). doi: 10.1088/1748-0221/13/01/P01005. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/4x3795h7
Journal of Instrumentation, vol 13, iss 1
Edwards, BNV; Bernard, E; Boulton, EM; Destefano, N; Gai, M; Horn, M; et al.(2018). Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber. Journal of Instrumentation, 13(1). doi: 10.1088/1748-0221/13/01/P01005. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/4x3795h7
© 2018 IOP Publishing Ltd and Sissa Medialab. We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::44174433c6750d6486fc3282b14880da
https://escholarship.org/uc/item/4x3795h7
https://escholarship.org/uc/item/4x3795h7
Autor:
Christopher G. Wahl, Zhong He, Y. Andy Boucher, Jason M. Jaworski, Willy Kaye, Feng Zhang, Weiyi Wang, Alexis King
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 784:377-381
Recently, H3D has designed and introduced a gamma-ray imaging spectrometer system named Polaris-H. Polaris-H was designed to perform gamma spectroscopy and imaging throughout nuclear power plants. It integrates a 3D-position-sensitive pixelated CZT d
Autor:
Steven Brown, Feng Zhang, Weiyi Wang, David Price Tefft, Thurston Matthews, Hao Yang, Kevin Moran, Christopher G. Wahl, Molly Ulrich, Jason M. Jaworski, Brian Kitchen, Timothy Slatina, Y. Andy Boucher, Willy Kaye, Zhong He
Publikováno v:
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
During nuclear power plant operation and maintenance, knowing the quantity and presence of radioisotopes in sub-system piping is critical for providing a comprehensive understanding of plant operation and for reducing worker dose. Two new instruments
Autor:
Moshe Gai, B. P. Tennyson, N. Destefano, B. N. Edwards, Christopher G. Wahl, E. M. Boulton, Ethan Bernard, S. A. Hertel, Daniel McKinsey, M. Horn, N.A. Larsen
Publikováno v:
Boulton, EM; Bernard, E; Destefano, N; Edwards, BNV; Gai, M; Hertel, SA; et al.(2017). Calibration of a two-phase xenon time projection chamber with a37Ar source. Journal of Instrumentation, 12(8). doi: 10.1088/1748-0221/12/08/P08004. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/5h07r6n6
Journal of Instrumentation, vol 12, iss 08
Journal of Instrumentation, vol 12, iss 8
Journal of Instrumentation, vol 12, iss 08
Journal of Instrumentation, vol 12, iss 8
We calibrate a two-phase xenon detector at 0.27 keV in the charge channel and at 2.8 keV in both the light and charge channels using a $^{37}$Ar source that is directly released into the detector. We map the light and charge yields as a function of e
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4cb6107a1744e6e50072c019521c8bfb
http://www.escholarship.org/uc/item/5h07r6n6
http://www.escholarship.org/uc/item/5h07r6n6
Model-Based Reconstruction of Spectral and Spatial Source Distribution for Objects With Known Motion
Publikováno v:
IEEE Transactions on Nuclear Science. 60:3981-3989
Radiation imaging has many applications ranging from health care to homeland security and defense, and source motion is present in many of these applications. When the motion profile of the source is known or otherwise estimated, one can use motion-c
Publikováno v:
IEEE Transactions on Nuclear Science. 59:1672-1680
In order to support analysis of data from 3D-position-sensitive gamma-ray detectors, a software package, UMImaging, has been designed and implemented. UMImaging is designed to apply to a wide range of hardware configurations and analysis needs. Its f