Autor:
Anirejuoritse Bafor, Regitze Gyldenholm Skals, Ming Shen, Christopher A Iobst, Ole Rahbek, Søren Kold, Marie Fridberg
Publikováno v:
Digital Health, Vol 10 (2024)
Objectives A grading system deployed for continuous at-home monitoring of pin sites would potentially increase the chances of early detection of pin-site infections and the commencement of early treatment. The first five grades of the Modified Gordon
Externí odkaz:
https://doaj.org/article/1aa3e7f1e9e24db49bb6b94a0d847312
Publikováno v:
Journal of Limb Lengthening & Reconstruction, Vol 8, Iss 3, Pp 69-80 (2022)
Context: Pin-site infections are a common complication associated with the use of external fixators. While many different pin-site care protocols have been described, there is no universally accepted and effective method to eliminate this issue. Furt
Externí odkaz:
https://doaj.org/article/df9179740c4447f287b5e3ff1ecd9940
Publikováno v:
Journal of Limb Lengthening & Reconstruction, Vol 5, Iss 1, Pp 37-40 (2019)
Context: Fibular osteotomy is a necessary element of most tibial procedures, but there is no consensus on the ideal location, orientation, or technique for the procedure. Aims: We surveyed limb reconstruction surgeons to learn how often a fibular ost
Externí odkaz:
https://doaj.org/article/82e848396a5649bba37d3636ff481ffc
Publikováno v:
Journal of Pediatric Orthopaedics. 43:232-236
Publikováno v:
Journal of Limb Lengthening & Reconstruction, Vol 3, Iss 1, Pp 45-51 (2017)
Background: Hexapod external fixators often incorporate bone lengthening as part of a multi-planar deformity correction plan. The hexapod struts, however, do not distract in the direction of bone lengthening. Their oblique orientation to the ring cre
Externí odkaz:
https://doaj.org/article/7ccecaa798c7421db8c0d864863bf9b3
Autor:
Christopher A Iobst
Publikováno v:
Journal of Limb Lengthening & Reconstruction, Vol 3, Iss 2, Pp 78-84 (2017)
Pin-track infections are a common problem with external fixation and any other implant that breaks the skin barrier. The literature is rich with reports and techniques for treating these infections, but lacks a universally accepted definition of a pi
Externí odkaz:
https://doaj.org/article/ac9dbaf2bcc844748a89e7b1a05d2bc1
Publikováno v:
Journal of Bone and Joint Surgery. 104:1419-1425
Publikováno v:
Current Orthopaedic Practice.
Publikováno v:
Current Orthopaedic Practice. 33:311-314
Autor:
Christopher A Iobst, Raymond W Liu
Publikováno v:
Journal of Limb Lengthening & Reconstruction, Vol 2, Iss 1, Pp 6-16 (2016)
Depending on the reference, pin track infection rates in external fixation surgery have been stated to be anywhere from 0% to 100%. We critically evaluated the pin track infection rate for external fixation by performing systematic review of the exte
Externí odkaz:
https://doaj.org/article/64e1a9c4058d4594bb3c5d7e43a6cf4c