Zobrazeno 1 - 10
of 38
pro vyhledávání: '"Choon Sik Jhun"'
Autor:
SCHEIB, CHRISTOPHER, NEWSWANGER, RAYMOND, CYSYK, JOSHUA, BOHNENBERGER, KARL, LUKIC, BRANKA, LICHONG XU, YEAGER, ERIC, BLETCHER, KIRBY, LEIBICH, PATRICK, JACKSON, QUANDASHIA, FLORY, HEIDI, TILLINGER, MINDY, WEISS, WILLIAM, ROSENBERG, GERSON, CHOON-SIK JHUN
Publikováno v:
ASAIO Journal; Oct2024, Vol. 70 Issue 10, p892-897, 6p
Autor:
Ray Newswanger, Walter E. Pae, John D. Reibson, Choon Sik Jhun, Heidi Flory, William J. Weiss, Gerson Rosenberg, Jenelle M. Izer, Joshua Cysyk
Publikováno v:
ASAIO Journal. 68:791-799
Current generation continuous flow assist devices to operate at a fixed speed, which limits preload response and exercise capacity in left ventricular assist device (LVAD) patients. A feedback control system was developed to automatically adjust pump
Autor:
Choon-Sik Jhun, Lichong Xu, Christopher Siedlecki, Carlo R. Bartoli, Eric Yeager, Branka Lukic, Christopher M. Scheib, Raymond Newswanger, Joshua P. Cysyk, Chan Shen, Karl Bohnenberger, William J. Weiss, Gerson Rosenberg
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992).
The loss of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in aortic stenosis (AS) and continuous-flow left ventricular assist devices (cf-LVADs) is believed to be associated with high turbulent blood shear. The objective of th
Autor:
Jenelle M. Izer, Eric Popjes, Choon Sik Jhun, Gerson Rosenberg, Walter E. Pae, Joshua Cysyk, Ray Newswanger, William J. Weiss
Publikováno v:
ASAIO J
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip fo
Autor:
Choon Sik Jhun, Jenelle M. Izer, Clark Joseph Brian, Branka Lukic, Heidi Flory, Joshua Cysyk, Ray Newswanger, John D. Reibson, Bradley Doxtater, Gerson Rosenberg, William J. Weiss
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 67(11)
We have miniaturized and optimized our implantable rotary blood pump developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the miniaturized Fontan c
Autor:
Bryan C. Good, Sailahari V. Ponnaluri, Choon Sik Jhun, Joshua Cysyk, Ray Newswanger, Gerson Rosenberg, Keefe B. Manning
Publikováno v:
ASAIO J
Supraphysiologic high shear stresses created in calcific aortic stenosis (AS) are known to cause hemostatic abnormalities, however, the relationship between the complex blood flows over the severity of AS and hemostatic abnormalities still remains un
Autor:
Gerson Rosenberg, Li Chong Xu, Ray Newswanger, William J. Weiss, Joshua Cysyk, Eric Yeager, John D. Reibson, Branka Lukic, Christopher A. Siedlecki, Choon Sik Jhun
Publikováno v:
Artificial Organs. 43:199-206
Despite the prevailing use of the continuous flow left ventricular assist devices (cf-LVAD), acquired von Willebrand syndrome (AvWS) associated with cf-LVAD still remains a major complication. As AvWS is known to be dependent on shear stress (τ) and
Autor:
Choon Sik Jhun, Steven Deutsch, William S. Pierce, Gerson Rosenberg, Keefe B. Manning, Christopher A. Siedlecki, William J. Weiss
Publikováno v:
Artificial Organs. 42:1119-1124
The existence of acquired von Willebrand syndrome (AVWS) in patients with continuous flow left ventricular assist devices (LVADs) is well documented and has been verified by numerous investigators. AVWS has not been observed to occur in pulsatile dev
Autor:
Eric Yeager, Keefe B. Manning, Choon Sik Jhun, Megan A. Stauffer, John D. Reibson, William J. Weiss, Ray Newswanger, Gerson Rosenberg, Joshua O. Taylor
Publikováno v:
ASAIO Journal. 64:63-69
Reynolds shear stress (RSS) has served as a metric for the effect of turbulence on hemolysis. Forstrom (1969) and Sallam and Hwang (1984) determined the RSS threshold for hemolysis to be 50,000 and 4,000 dyne/cm, respectively, using a turbulent jet.
Autor:
Bradley Doxtater, Ray Newswanger, Joseph B. Clark, Jenelle M. Izer, Gerson Rosenberg, Heidi A. Finicle, John D. Reibson, Choon Sik Jhun, William J. Weiss, Joshua Cysyk
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 65(6)
An implantable rotary blood pump was developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the pump in vivo in a 30 day sheep study. Pump speed was