Zobrazeno 1 - 10
of 32
pro vyhledávání: '"Cho-Chiang Shih"'
Autor:
Hongyu Zhou, Jianmin Ding, Yan Zhou, Yandong Wang, Lei Zhao, Cho-Chiang Shih, Jingping Xu, Jianan Wang, Ling Tong, Zhouye Chen, Qizhong Lin, Xiang Jing
Publikováno v:
BMC Medical Imaging, Vol 24, Iss 1, Pp 1-10 (2024)
Abstract Background Contrast-enhanced ultrasound (CEUS) is considered as an efficient tool for focal liver lesion characterization, given it allows real-time scanning and provides dynamic tissue perfusion information. An accurate diagnosis of liver l
Externí odkaz:
https://doaj.org/article/6339eced0b854ccf84ada337cd763740
Publikováno v:
Royal Society Open Science, Vol 5, Iss 4 (2018)
The ability to measure the elastic properties of plaques and vessels would be useful in clinical diagnoses, particularly for detecting a vulnerable plaque. This study demonstrates the feasibility of the combination of intravascular ultrasound (IVUS)
Externí odkaz:
https://doaj.org/article/db3788365ed14d9ca9db860c26471639
Autor:
Pei-Yu Chen, Cho-Chiang Shih, Wei-Chen Lin, Teng Ma, Qifa Zhou, K. Kirk Shung, Chih-Chung Huang
Publikováno v:
Sensors, Vol 18, Iss 12, p 4244 (2018)
Estimating the corneal elasticity can provide valuable information for corneal pathologies and treatments. Ophthalmologic pathologies will invariably cause changes to the elasticity of the cornea. For example, keratoconus and the phototoxic effects o
Externí odkaz:
https://doaj.org/article/2e12ff10152c4c32b23f544ef99500c2
Publikováno v:
IEEE Transactions on Biomedical Engineering. 68:2637-2644
Objective: Estimating the elasticity distribution in the cornea is important because corneal elasticity is usually influenced by corneal pathologies and surgical treatments, especially for early corneal sclerosis. Because the thickness of the cornea
Autor:
Yung-Chun Chang, Yan-Chun Hsing, Yu-Wen Chiu, Cho-Chiang Shih, Jun-Hong Lin, Shih-Hsin Hsiao, Koji Sakai, Kai-Hsiung Ko, Cheng-Yu Chen
Publikováno v:
Journal of Personalized Medicine; Volume 12; Issue 3; Pages: 417
Radiology report generation through chest radiography interpretation is a time-consuming task that involves the interpretation of images by expert radiologists. It is common for fatigue-induced diagnostic error to occur, and especially difficult in a
Publikováno v:
Ultrasonics. 74:11-20
Ultrasound imaging has been extensively used for determining the severity of carotid atherosclerotic stenosis. In particular, the morphological characterization of carotid plaques can be performed for risk stratification of patients. However, using 2
Publikováno v:
IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 67(1)
Tendon stiffness plays an important role in the tendon healing process, and many studies have indicated that measuring the shear wave velocity (SWV) on tendons relates to their stiffness. Because the thickness of hand tendons is a few millimeters, hi
Publikováno v:
Ultrasonics. 70:64-74
The ability to measure the elastic properties of plaques and vessels is significant in clinical diagnosis, particularly for detecting a vulnerable plaque. A novel concept of combining intravascular ultrasound (IVUS) imaging and acoustic radiation for
Publikováno v:
Medical Physics. 43:148-158
Purpose: Information about tendon displacement is important for allowing clinicians to not only quantify preoperative tendon injuries but also to identify any adhesive scaring between tendon and adjacent tissue. The Fisher-Tippett (FT) similarity mea
Autor:
Cho Chiang Shih, Xuejun Qian, Teng Ma, K. Kirk Shung, Zhaolong Han, Chih-Chung Huang, Qifa Zhou
Publikováno v:
IEEE transactions on medical imaging. 37(8)
Characterizing the viscoelastic properties of thin-layer tissues with micro-level thickness has long remained challenging. Recently, several micro-elastography techniques have been developed to improve the spatial resolution. However, most of these t