Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Cho Man Tsui"'
Publikováno v:
NCSLI Measure. 14:34-39
This paper presents the ultrasonic flaw detectors calibration system at Standards and Calibration Laboratory (SCL) developed in accordance with the Group 2 tests of ISO 22232-1:2020. The calibration system contains a delay-pulse generator, a function
Autor:
Hau Wah Lai, Cho Man Tsui
Publikováno v:
NCSL International measure. 13:23-35
This paper presents a t wo-dimensional 10 x 10 LED array system developed in-house at t he Standards and Calibration Laboratory (SCL) for the calibration of timing parameters of still image cameras and video cameras. In this paper, the circuit design
Publikováno v:
NCSL International measure. 13:28-39
This paper describes a procedure and a computer-aided system developed by the Standards and Calibration Laboratory (SCL) for verification of voltage dip and short interruption generators in accordance with the international standard IEC 61000-4-11:20
Publikováno v:
NCSL International Workshop & Symposium Conference Proceedings 2021.
This paper presents the procedure developed at SCL for the calibration of loop antennas for test frequencies from 9 kHz to 30 MHz in accordance with CISPR 16-1-6:2014+AMD1:2017. The background, measurement model and uncertainty components are introdu
Publikováno v:
NCSLI Measure. 12:41-56
The GUM Supplement 2 describes a Monte Carlo Method (MCM) for evaluating measurement models with more than one output quantity. Such models are common in electrical metrology where the measurands m...
Publikováno v:
2019 URSI Asia-Pacific Radio Science Conference (AP-RASC).
In 2011, the Standards and Calibration Laboratory (SCL) developed the video totalize method for calibration of stopwatches with the use of an in-house designed synchronous counter [1]. All digits of the LED display for the counter are updated synchro
Autor:
Srdan Calija, Cho Man Tsui, Jon Bartholomew, Stephane Solve, S.-L.S. Yang, Kyu-Tae Kim, Abdullah M Alrobaish
Publikováno v:
Metrologia. 57:01012
This report presents the GULFMET key comparison (GULFMET.EM.BIPM-K11) results of DC voltages at the 1.018 V and 10 V with two travelling electronic DC reference standards. This comparison was supported by the BIPM and GULFMET associate members, KRISS
Provision of Traceable Calibration Services at SCL to Underpin Development of Smart City Initiatives
Publikováno v:
2018 IEEE Symposium on Product Compliance Engineering - Asia (ISPCE-CN).
Smart City is built on networks of Internet of Things (IoT) and sensors. Calibration is important to ensure correct operations of the sensors which in turn improve the reliability and safety of the whole system. The Standards and Calibration Laborato
Publikováno v:
NCSLI Measure. 7:48-54
In October 2011, a new guidance document “Evaluation of measurement data – Supplement 2 to the ‘Guide to the expression of uncertainty in measurement’ – Extension to any number of output quantities...
Autor:
Cho-man Tsui, Hon-man Chan
Publikováno v:
NCSLI Measure. 7:26-27