Zobrazeno 1 - 10
of 20
pro vyhledávání: '"Cho Hiroaki"'
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Hiromasa Yoshizumi, Masayuki Hikita, Masahiro Kozako, Cho Hiroaki, Nakamura Yusuke, Yuuki Fujii
Publikováno v:
IEEJ Transactions on Fundamentals and Materials. 139:154-160
Publikováno v:
2020 8th International Conference on Condition Monitoring and Diagnosis (CMD).
In this paper, a non-destructive inspection method by using THz waves will be discussed to detect defects in epoxy resin, which is widely used as an insulating material in power equipment. Fundamental data were obtained, such as the absorption rate o
Publikováno v:
Lecture Notes in Electrical Engineering ISBN: 9783030316754
Partial Discharge (PD) is one of the most harmful phenomenon in high voltage electrical equipment. While measurement of PD is widely accepted to examine whether insulation performance of the equipment is deteriorated or not, external noise interferen
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9ae648160cc768f52271b2afcce9fbbf
https://doi.org/10.1007/978-3-030-31676-1_47
https://doi.org/10.1007/978-3-030-31676-1_47
Autor:
Hiromasa Yoshizumi, Masahiro Kozako, Masayuki Hikita, Cho Hiroaki, Nakamura Yusuke, Yusuke Nakano, Yuuki Fujii
Publikováno v:
2018 Condition Monitoring and Diagnosis (CMD).
Transient earth voltage (TEV) detection method is drawing attention for its readiness to be installed just on the outer wall of existing equipment, and is useful for partial discharge (PD) detection. The purpose of this research is to establish relia
Publikováno v:
2017 4th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST).
Partial discharge detection is useful for insulation diagnosis of switchgear. Since a partial discharge can be easily measured by attaching a sensor to a metal casing, we have been studying practical applications of the transient earth voltage (TEV)
Autor:
Yuuki Fujii, Masahiro Kozako, Masayuki Hikita, Takaaki Koga, Nakamura Yusuke, Hiromasa Yoshizumi, Cho Hiroaki
Publikováno v:
2017 International Symposium on Electrical Insulating Materials (ISEIM).
This paper deals with advancement of insulation diagnosis technology for high voltage equipment by partial discharge (PD) detection using transient earth voltage (TEV) detection method. Our previous study showed that detected TEV signal contains both
Publikováno v:
2016 IEEE International Conference on Dielectrics (ICD).
This paper discusses the influence of pressure in a defect on time evolution of Partial discharge (PD) characteristics and lifetime characteristics of an insulation model of a molded transformer. Experimental results show that the time evolution of P
Autor:
Takeuchi Miwa, Cho Hiroaki, Takahiro Imai, Hiroki Sekiya, Motofumi Tanaka, Masahiro Asayama, Kenichi Yamazaki, Tamon Ozaki, Toshiki Osako
Publikováno v:
2012 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.
Nanocomposite techniques are used to improve the electrical properties of epoxy materials, for example, insulation breakdown strength and partial discharge resistance. In the first step, we prepared epoxy-based nanocomposites by using hydrophobic epo
Autor:
Toshiki Osako, Hiroki Sekiya, Cho Hiroaki, Kenichi Yamazaki, Takahiro Imai, Masahiro Asayama, Tamon Ozaki, Motofumi Tanaka
Publikováno v:
2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.