Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Chiara Dolores Soffientini"'
Autor:
Massimo Castellani, Chiara Dolores Soffientini, Giuseppe Baselli, Elisabetta De Bernardi, Felicia Zito
Publikováno v:
Medical Physics. 43:2662-2675
Purpose: Quantitative 18F-fluorodeoxyglucose positron emission tomography is limited by the uncertainty in lesion delineation due to poor SNR, low resolution, and partial volume effects, subsequently impacting oncological assessment, treatment planni
Autor:
Felicia Zito, Elisabetta De Bernardi, Rosangela Casati, Giuseppe Baselli, Chiara Dolores Soffientini
PURPOSE Design, realization, scan, and characterization of a phantom for PET Automatic Segmentation (PET-AS) assessment are presented. Radioactive zeolites immersed in a radioactive heterogeneous background simulate realistic wall-less lesions with k
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a798ddcceaad6484b404efe0c9b3e3ab
http://hdl.handle.net/11311/1039510
http://hdl.handle.net/11311/1039510
Autor:
Giancarlo Terraneo, Chiara Dolores Soffientini, Marco de Curtis, Massimo Cametti, Elisabetta De Bernardi, Giuseppe Baselli, Giuseppe Resnati, Gian Luca Breschi, Pierangelo Metrangolo, Ileana Zucca, Roberto Spreafico, Alfonso Mastropietro
Publikováno v:
Journal of Magnetic Resonance Imaging. 40:162-170
Purpose To optimize signal-to-noise ratio (SNR) in fast spin echo (rapid acquisition with relaxation enhancement [RARE]) sequences and to improve sensitivity in 19F magnetic resonance imaging (MRI) on a 7T preclinical MRI system, based on a previous
Autor:
Chiara Dolores Soffientini, Giuseppe Baselli, Elisabetta De Bernardi, Chiara Gianoli, Felicia Zito, Elena Faggiano
Publikováno v:
RTSI
A review of recent works by our group in the segmentation and quantification of oncological lesions in 18-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) images is given, stressing the underlying model assumption. In a first approach, a
Autor:
Chiara Dolores, Soffientini, Elisabetta, De Bernardi, Felicia, Zito, Massimo, Castellani, Giuseppe, Baselli
Purpose: Quantitative 18F-fluorodeoxyglucose positron emission tomography is limited by the uncertainty in lesion delineation due to poor SNR, low resolution, and partial volume effects, subsequently impacting oncological assessment, treatment planni
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=pmid_dedup__::f64898b8e6cbee1c02a785c42b314579
http://hdl.handle.net/10281/132919
http://hdl.handle.net/10281/132919
Autor:
Cristina Canzi, Paolo Gerundini, Felicia Zito, Elisabetta De Bernardi, Giuseppe Baselli, Chiara Dolores Soffientini, Rosangela Casati
Publikováno v:
Medical Physics. 39:5353-5361
Purpose: In recent years, segmentation algorithms and activity quantification methods have been proposed for oncological 18F- fluorodeoxyglucose (FDG) PET. A full assessment of these algorithms, necessary for a clinical transfer, requires a validatio
Autor:
Alfonso, Mastropietro, Elisabetta, De Bernardi, Gian Luca, Breschi, Ileana, Zucca, Massimo, Cametti, Chiara Dolores, Soffientini, Marco, de Curtis, Giancarlo, Terraneo, Pierangelo, Metrangolo, Roberto, Spreafico, Giuseppe, Resnati, Giuseppe, Baselli
Publikováno v:
Journal of magnetic resonance imaging : JMRI. 40(1)
To optimize signal-to-noise ratio (SNR) in fast spin echo (rapid acquisition with relaxation enhancement [RARE]) sequences and to improve sensitivity in ¹⁹F magnetic resonance imaging (MRI) on a 7T preclinical MRI system, based on a previous exper
Autor:
Matteo Caffini, Giuseppe Baselli, Sara Cocco, Ileana Zucca, Alfonso Mastropietro, Chiara Dolores Soffientini, Alessandro Scotti, Maria Grazia Bruzzone
In 19 F-MRI studies limiting factors are the presence of a low signal due to the low concentration of 19 F-nuclei, necessary for biological applications, and the inherent low sensitivity of MRI. Hence, acquiring images using the pulse sequence with t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f21ecabf4333a6a3f4ed066c922bec37
http://hdl.handle.net/11311/867736
http://hdl.handle.net/11311/867736
Publikováno v:
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).
In this work we propose a strategy to jointly estimate activity and borders of oncological lesions in PET/CT. The starting step is constituted by a lesion contouring on PET image volume and by a Gaussian Mixture Model (GMM) clustering which individua