Zobrazeno 1 - 10
of 34
pro vyhledávání: '"Cheolwoong Ko"'
Publikováno v:
Applied Bionics and Biomechanics, Vol 2017 (2017)
A biomechanical test is a good evaluation method that describes the structural, functional, and pathological differences in the bones, such as osteoporosis and fracture. The tensile test, compression test, and bending test are generally performed to
Externí odkaz:
https://doaj.org/article/7359c0be4a5149209bbb223b711b5364
A comparative study of the methods for measuring lumbar intervertebral gap using radiographic images
Publikováno v:
International Journal of Precision Engineering and Manufacturing. 17:801-805
Anterior and posterior intervertebral gap of lumbar spine is important when developing the spinal implants regarding lumbar system. However, the measuring methods continue to be still controversial because of the absence of a standardized measurement
Publikováno v:
Applied Bionics and Biomechanics
Applied Bionics and Biomechanics, Vol 2017 (2017)
Applied Bionics and Biomechanics, Vol 2017 (2017)
A biomechanical test is a good evaluation method that describes the structural, functional, and pathological differences in the bones, such as osteoporosis and fracture. The tensile test, compression test, and bending test are generally performed to
Autor:
Changsoo Chon, Sangkuy Han, Donghyun Seo, Jihyung Park, Bokku Kang, Hansung Kim, Keyoungjin Chun, Cheolwoong Ko
The purpose of the study is to develop a finite element model based on 3D bone structural images of Micro-CT and to analyze the stress distribution for the osteoporosis mouse femora. In this study, results of finite element analysis show that the ear
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::06ee255d474c5399fa037fd0ac2912bf
Publikováno v:
International Journal for Numerical Methods in Biomedical Engineering. 34:e2967
This study proposed a way to design femur fracture fixation plates made of shape memory alloy based on computed tomography (CT) images of Korean cadaveric femurs. To this end, 3 major design factors of femur fracture fixation plates (circumference an
Autor:
Thomas D. Brown, Cheolwoong Ko
Publikováno v:
Computer Methods in Biomechanics and Biomedical Engineering. 10:343-349
Carpal tunnel syndrome (CTS) is among the most important of the family of musculoskeletal disorders caused by chronic peripheral nerve compression. Despite the large body of research in many disciplinary areas aimed at reducing CTS incidence and/or s
Autor:
Sadayuki Ujihashi, Cheolwoong Ko, Hiroyuki Mitsuishi, Kazuo Takakuda, Norio Inou, Koshiro Ono
Publikováno v:
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A. 67:342-348
Many requirements such as safety, lightness and comfort are necessary to helmets for sports and riding. Many studies regarding basic functions of helmets including safety problems were reported. In the previous studies on safety problems, however, it
Publikováno v:
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME. :227-228
Publikováno v:
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME. :557-558
Publikováno v:
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME. :441-442