Zobrazeno 1 - 10
of 29
pro vyhledávání: '"Cheng-Teng Hsu"'
Autor:
Tse-En Wang, Chun-I. Lee, Chun-Chia Huang, Hui-Mei Tsao, Hui-Chen Chang, Li-Sheng Chang, T. Arthur Chang, Maw-Sheng Lee, Cheng-Teng Hsu
Publikováno v:
Scientific Reports, Vol 13, Iss 1, Pp 1-10 (2023)
Abstract Neutral comet assay has been available for two decades to evaluate sperm double-strand breaks (DSBs). However, its clinical usability is limited due to its complex and time-consuming procedure, as well as the lack of a standardized scoring s
Externí odkaz:
https://doaj.org/article/9ff10247150c46c9b8bbe9d082bbac90
Autor:
Cheng-Teng Hsu, 徐振騰
94
The group has had a long-standing interest in chemical and biological sensors and continues to make advances in the preparation of novel chemically modified screen-printed electrodes. The development of a device for single-drop whole blood an
The group has had a long-standing interest in chemical and biological sensors and continues to make advances in the preparation of novel chemically modified screen-printed electrodes. The development of a device for single-drop whole blood an
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/53693862016987570019
Autor:
Cheng‐Teng Hsu, Chun‐I. Lee, Chun‐Chia Huang, Tse‐En Wang, Hui‐Chen Chang, Li‐Sheng Chang, Maw‐Sheng Lee
Publikováno v:
Andrology.
Publikováno v:
Fertility and Sterility. 116:e347-e348
Publikováno v:
Fertility and Sterility. 116:e343
Publikováno v:
Fertility and Sterility. 114:e353-e354
Publikováno v:
Fertility and Sterility. 114:e372
Publikováno v:
Clinica Chimica Acta. 437:62-65
Background In response to the problem of erroneous readings due to miscoding when performing self-monitoring blood glucose (SMBG), this study introduces a user-friendly SMBG biosensor with an innovative auto-coding module on the meter and strip. Actu
Autor:
Govindan Muthuraman, Hsieh-Hsun Chung, Mei-Hsin Chiu, Wan-Ling Cheng, Jyh-Myng Zen, Cheng-Teng Hsu
Publikováno v:
Biosensors and Bioelectronics. 24:3008-3013
A screen-printed silver strip with three-electrode configuration of Ag-working, Ag-counter and Ag/Ag(x)O reference electrodes was developed for simultaneous determination of chloride, bromide and iodide in aqueous solutions. It was fabricated simply
Autor:
Jyh-Myng Zen, Cheng-Teng Hsu, Jyh-Cheng Chen, Hsiao-Jing Tseng, Govindan Muthuraman, Jyh-Harng Ke
Publikováno v:
Sensors and Actuators B: Chemical. 130:614-619
The thermoelectrochemistry of ascorbic acid (AA) at a disposable screen-printed carbon electrode (SPE) was studied in this paper. The response of AA is greatly suppressed at higher temperatures when the electrolyte solution containing AA is directly