Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Charles W. Wilkerson"'
Autor:
Mark B. Chadwick, William B. Wilson, Phillip G. Young, D. G. Madland, R. E. MacFarlane, Charles W. Wilkerson, Patrick Talou, Toshihiko Kawano
Publikováno v:
Nuclear Data Sheets. 108:2589-2654
We have completed new evaluations for several actinides in the ENDF/B-VII database and have extensively modified existing evaluations for several other actinides. We compare calculations using the new evaluations with critical assembly reaction rate
Autor:
Charles W. Wilkerson, Mark B. Chadwick, Patrick Talou, Holly R. Trellue, Phillip G. Young, S.C. Frankle, R. E. MacFarlane, Toshihiko Kawano
Publikováno v:
Nuclear Data Sheets. 108:2716-2741
We describe new dosimetry (radiochemical) ENDF evaluations for yttrium, iridium, and thulium. These LANL2006 evaluations were based upon measured data and on nuclear model cross section calculations. In the case of iridium and yttrium, new measuremen
Publikováno v:
International Journal of Mass Spectrometry. 212:197-204
We present results for the simultaneous detection of volatile organic compounds, semivolatile organic compounds, and organometallic compounds in air and water by using membrane introduction ion trap mass spectrometry. In these experiments, a membrane
Publikováno v:
Analytical Chemistry. 68:701-707
A new inlet system for fast gas chromatography has been built in which analyte compounds in the gas phase are cryogenically trapped onto a sample loop, isolated, revaporized, and injected. Sample loops are constructed of 20 cm lengths of 50 and 100
Publikováno v:
Analytical chemistry. 68(17)
The performance of two cryofocusing injectors for fast gas chromatography has been studied. The first system traps analytes onto bare metal tubes and rapidly vaporizes them upon ballistically heating the tube using a capacitance discharge. The second
Autor:
James H. Jett, Alberto Haces, John C. Martin, Po Jen Shih, Mitchell E. Johnson, Charles W. Wilkerson, John D. Harding, Peter M. Goodwin, Babetta L. Marrone, Richard A. Keller, J.A. Schecker, W. Patrick Ambrose
Publikováno v:
Berichte der Bunsengesellschaft für physikalische Chemie. 97:1535-1541
We are developing a laser-based technique for the rapid sequencing of 40-kb or larger fragments of DNA at a rate of 100 to 1000 bases per second. Our approach relies on fluorescent labeling of the bases in a single fragment of DNA, attachment of this
Publikováno v:
Analytical Chemistry. 65:1240-1246
The statistical properties of maximum likelihood (ML) and least-squares (LS) estimators for the exponential decay parameters [Gamma](rate) and [tau] (lifetime) are examined for finite observation time (T) and a small number of counts (N). The ML esti
Publikováno v:
Applied optics. 30(27)
Picosecond light pulses are used to generate multiple wavelengths by means of stimulated Raman scattering. A review of the processes involved is presented, followed by a discussion of the experimental apparatus. Stokes and anti-Stokes Raman-shifted l
Publikováno v:
Chemical Physics Letters. 174:377-384
Two-step laser photoelectron spectroscopy with temporally separated picosecond excitation and ionization light pulses is used to measure the rate of intramolecular vibrational relaxation (IVR) in jet-cooled trans- p - n -butylaniline. Qualitatively s
Autor:
James P. Reilly, Charles W. Wilkerson
Publikováno v:
Analytical Chemistry. 62:1804-1808
Etude par GC/MS et ionisation laser de 4 benzenes halogenes (fluoro-, chloro-, bromo- et iodobenzene), mesure des temps de vie des etats excites S1 et discussion des variations observees