Zobrazeno 1 - 10
of 53
pro vyhledávání: '"Charge Monitors and Other Instruments"'
A Two-frequency method has been implemented for bunch length measurement at Shanghai Synchrotron Radiation Facility (SSRF). It is based on the information from two harmonic frequencies of Flourier Transformation of longitudinal charge distribution. W
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::bfa7d8a85d005df182198aa67835db23
The APS Upgrade storage ring multi-bend acromat lattice uses 1000 individually-powered multi-pole magnets operating at current levels to ~260A. Requirements for power-supply stability, repeatability and reproducibility are of the order of 10 ppm. MBA
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::3a6636cf61d7564b53081cad90ea926c
An air parallel-plate ion chamber, which acts as a dose monitor for the beam delivery system in Huazhong University of Science and Technology Proton Therapy Facility(HUST-PTF), is designed as a redundant twin ionization chamber in order to meet the s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::938e7a5d1095579b92340384b07a9b0f
The measurement of beam charge is a fundamental re-quirement to all particle accelerators facility. In this paper, using the TM010 mode of the cavity BPM to measure the beam charge will be introduced. The data processing methods including harmonic an
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::906d4ed74571fb61d9952fc364b6c6ad
Autor:
Sieber, Thomas, De Gersem, Herbert, Fernandes, Miguel, Golm, Jessica, Jones, Robert, Kowina, Piotr, Kurian, Febin, Marsic, Nicolas, Neubert, Ralf, Reeg, Hansjörg, Schmelz, Matthias, Schmidl, Frank, Schwickert, Marcus, Seidel, Paul, Søby, Lars, Stöhlker, Thomas, Stolz, Ronny, Tan, Jocelyn, Tranquille, Gerard, Tympel, Volker, Welsch, Carsten, Zakosarenko, Vyacheslav
Triggered by the need for current measurement in the nA range for slow extracted beams and for the beams in the storage rings at FAIR and CERN, the idea of the CCC as a current transformer has been revitalized during the last ten years. Compared to t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::386ca46e510089639128f7e8ccabc456
Autor:
Tympel, Volker, Kurian, Febin, Neubert, Ralf, Schmelz, Matthias, Schmidl, Frank, Schwickert, Marcus, Seidel, Paul, Sieber, Thomas, Stöhlker, Thomas, Stolz, Ronny, Zakosarenko, Vyacheslav
New versions of Cryogenic Current Comparator (CCC) sensors with eXtended Dimensions (CCC-XD) for beam line diameters up to 150 mm (necessary for the planned new Facility for Antiproton and Ion Research (FAIR) at GSI (Gesellschaft für Schwerionenfors
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9e0b3d2e26927547e2cbcdadc3c580dc
Harmonic method is very useful when we try to obtain the bunch length, while its resolution is always influenced by many factors. In this paper, the relations between resolution and working frequencies of two cavities are given by mathematical deduct
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7c64d72fb39dab5567a0d518afa94825
Accelerator-driven system (ADS) is discussed as one of the efficient device to transmute long-lived nuclides. For the efficient transmutation of the minor actinide (MA), precise prediction of neutronics of ADS is indispensable. The Transmutation Phys
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::18e1f6067dacce5cab8ed69cac1861c3
As Tunnel Magneto Resistance (TMR ) sensor reaches high resolution and low noise, a new principle CT based on TMR sensor is developed. Simulations and other methods for improving the resolution and accuracy are done .The linearity and bandwidth of th
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::bec7946881425517d20f72bbe74f6441
Autor:
Miller, Toby, Blaskiewicz, Michael, Boucher, Remi, Fedotov, Alexei, Gassner, David, Germain, Cedric, Germain, Jean-Claud, Kewisch, Jorg, Minty, Michiko, Seletskiy, Sergei, Song, Honghai, Thieberger, Peter, Wanderer, Peter
Publikováno v:
6th International Beam Instrumentation Conference
6th International Beam Instrumentation Conference, Aug 2017, Grand Rapids, United States. pp.WEPCF05, ⟨10.18429/JACoW-IBIC2017-WEPCF05⟩
6th International Beam Instrumentation Conference, Aug 2017, Grand Rapids, United States. pp.WEPCF05, ⟨10.18429/JACoW-IBIC2017-WEPCF05⟩
Low Energy RHIC electron Cooling (LEReC) is planned during a 7.7 - 20 GeV/n run with Au+79 starting in 2019 (200 GeV/n center-of-mass typical), to explore the existence and location of the QCD critical point. An electron accelerator for LEReC is bein
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2a1c4d5655c45d61084a5227560d8c27
https://hal.archives-ouvertes.fr/hal-02065813
https://hal.archives-ouvertes.fr/hal-02065813