Zobrazeno 1 - 10
of 36
pro vyhledávání: '"Ch. Stamm"'
Publikováno v:
Cardiology Research and Practice, Vol 2011 (2011)
Under conventional heart failure therapy, inflammatory cardiomyopathy usually has a progressive course, merging for alternative interventional strategies. There is accumulating support for the application of cellular transplantation as a strategy to
Externí odkaz:
https://doaj.org/article/f5ff8fe4aafc44c3a0f93065ba36d726
Publikováno v:
Cardiology Research and Practice
Cardiology Research and Practice, Vol 2011 (2011)
Cardiology Research and Practice, Vol 2011 (2011)
Under conventional heart failure therapy, inflammatory cardiomyopathy usually has a progressive course, merging for alternative interventional strategies. There is accumulating support for the application of cellular transplantation as a strategy to
Publikováno v:
Optics Communications. 153:347-359
Integrated-optical difference interferometers – operated at a single wavelength – were developed in our group as biosensors for monitoring bio-specific interactions in real time. Their potentially very high resolution cannot be exploited in pract
Publikováno v:
Sensors and Actuators B: Chemical. 39:316-323
The object of the present paper is to report on new versions of the difference interferometer which have been sucessfully used for refractometric measurements and for humidity- and biosensing, i.e., for real-time monitoring of the adsorption of prote
Publikováno v:
Sensors and Actuators B: Chemical. 31:203-207
We have used an integrated optical difference (or polarimetric) interferometer as an immunosensor. The goat anti-rabbit IgG antibodies are immobilized on a planar SiO 2 TiO 2 waveguide as receptor layer. The corresponding ligand, the antigen rabbi
Publikováno v:
Sensors and Actuators B: Chemical. 18:183-187
An integrated optical difference (or polarimetric) interferometer has been used for real-time monitoring of protein adsorption on an SiO 2 —TiO 2 waveguide surface. The different adsorption behaviours of avidin, NeutrAvidin and streptavidin are stu
Publikováno v:
Sensors and Actuators B: Chemical. 11:177-181
We have successfully used an integrated optical (IO) difference (or polarimetric) interferometer (1) as a refractometer for liquid samples, (2) for monitoring protein adsorption, and (3) as an affinity sensor. The affinity reaction between avidin ads
Publikováno v:
Sensors and Actuators A: Physical. 25:185-188
We demonstrate a novel integrated optical interferometer which responds to changes in the relative humidity of gaseous samples and to changes in the refractive index of liquid samples. This common-path interferometer, which can be fabricated without
Publikováno v:
Sensors and Actuators B: Chemical. 1:585-588
We have demonstrated that output grating couplers on thin SiO2-TiO2 waveguides are sensors which respond (i) with sub-monomolecular sensitivity to the adsorption of molecules out of a gaseous or liquid sample covering the waveguide in the grating reg
Publikováno v:
Vadose Zone Journal
Scopus-Elsevier
Scopus-Elsevier
Many remote sensing applications, including those of future space missions, require accurate knowledge of the influence of topsoil structure on the water content as measured using L-band radiometry. We report on field-measured L-band (1.4 GHz) microw
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::39ed71379f8874222f379fe7b063e504
http://gfzpublic.gfz-potsdam.de/pubman/item/escidoc:242211
http://gfzpublic.gfz-potsdam.de/pubman/item/escidoc:242211