Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Catherine G. Knier"'
Autor:
Tanner J. Ferguson, Catherine G. Knier, Uttio Roy Chowdhury, Kjerseten J. Monson, Michael Greenwood, Russell J. Swan, Richard Gorham, John P. Berdahl, Michael P. Fautsch
Publikováno v:
Ophthalmology and Therapy, Vol 9, Iss 1, Pp 127-137 (2020)
Abstract Purpose To investigate the precision and accuracy of IOP measurements using a pneumatonometer and a tonometer tip cover (Tono-Pen® tip cover) acting as a membrane between a cadaver eye model and pneumatonometer probe. Methods A total of 480
Externí odkaz:
https://doaj.org/article/2e7149b0ff4545e49e5e0dc6c70aa697
Publikováno v:
Journal of Ophthalmology, Vol 2020 (2020)
Elevated intraocular pressure (IOP) is the most prevalent risk factor for primary open-angle glaucoma. However, IOP alone does not fully describe a mechanical basis for disease in patients with normal tension glaucoma or primary open-angle glaucoma.
Externí odkaz:
https://doaj.org/article/f6c46f1a7585497d9862e1d2f7e0eb56
Autor:
Camilo A. Mejia, Jason M. Sargent, Cheryl L. Khanna, Armin Garmany, Felix F. Kung, Catherine G. Knier, Nouran Sabbagh, Sepideh Jamali Dogahe, David O. Hodge
Publikováno v:
J Glaucoma
Prcis Kaplan-Meier analysis was used to compare the rate of corneal grafting after glaucoma drainage device placement in pediatric and adult patients. Adults were at an increased risk of receiving a corneal graft after device placement. Purpose The g
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6bbbb86c64de206ea1db7d7aa9ad7dbd
https://europepmc.org/articles/PMC8043241/
https://europepmc.org/articles/PMC8043241/
Autor:
Sepideh Jamali Dogahe, Nouran Sabbagh, Cheryl L. Khanna, Camilo A. Mejia, Jason M. Sargent, Armin Garmany, Felix F. Kung, David O. Hodge, Catherine G. Knier
Publikováno v:
J Glaucoma
Prcis In this longitudinal study of patients with open-angle (OAG), pseudoexfoliative (PXE), or neovascular glaucoma (NVG) receiving glaucoma drainage devices (GDD), posttube cumulative rates of reoperation, corneal graft, and visually threatening co
Publikováno v:
Journal of Ophthalmology, Vol 2020 (2020)
Journal of Ophthalmology
Journal of Ophthalmology
Elevated intraocular pressure (IOP) is the most prevalent risk factor for primary open-angle glaucoma. However, IOP alone does not fully describe a mechanical basis for disease in patients with normal tension glaucoma or primary open-angle glaucoma.
Publikováno v:
J Glaucoma
PReCIS:: Over 10 years in a tertiary care setting, glaucoma drainage devices (GDDs) have not increased as a reason for keratoplasty. PURPOSE The purpose of this study was to determine whether the reasons for keratoplasty have changed between 10 years
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6980ee19c65e8f4cce7b8c7bac91d49f
https://europepmc.org/articles/PMC6773479/
https://europepmc.org/articles/PMC6773479/