Zobrazeno 1 - 10
of 14
pro vyhledávání: '"Casey R. McAlpin"'
Autor:
Casey R. McAlpin, Kejing Li, Michael Batzle, Andrew M. Herring, Matthew W. Liberatore, Monica Vasiliu, Kent J. Voorhees, David A. Dixon, Yuan Yang
Publikováno v:
Fuel. 157:16-20
Gilsonite is a natural fossil resource, similar to a petroleum asphalt high in asphaltenes. Asphaltenes are a class of organic compounds operationally defined based on their solubility in organic solvents, and as a result there is wide range of poten
Publikováno v:
Rapid Communications in Mass Spectrometry. 29:2007-2012
Rationale Bacterial fatty acid profiling is a well-established technique for bacterial identification. Current methods involving esterification and gas chromatography/mass spectrometry (GC/MS) or matrix-assisted laser desorption/ionization (MALDI) an
Autor:
Kirk R. Jensen, Kent J. Voorhees, Robert B. Cody, Christopher Cox, Jon Rees, Masaaki Ubukata, Casey R. McAlpin
Publikováno v:
Journal of Mass Spectrometry. 48:850-855
Bacterial fatty acid profiling is a well-established technique for bacterial identification. Ten bacteria were analyzed using both positive- and negative-ion modes with a modified matrix-assisted laser desorption ionization mass spectrometry (MALDI M
Autor:
Casey R. McAlpin, Kent J. Voorhees
Publikováno v:
Rapid Communications in Mass Spectrometry. 27:1763-1768
RATIONALE Applications of metal oxide laser ionization mass spectrometry (MOLI MS) have been limited to compounds that provide protons for ionization upon adsorption to a metal oxide surface. The addition of a small molecule, which can act as a proto
Publikováno v:
Journal of Analytical and Applied Pyrolysis. 98:201-206
A procedure for lipid analysis using catalytic pyrolysis metal oxide laser ionization mass spectrometry (CP-MOLI MS) is described. When surface activated CaO is mixed with a lipid sample and analyzed using CP-MOLI MS, cleavage of lipids occurs by a r
Publikováno v:
Analytical Chemistry. 84:7677-7683
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used for lipid analysis; however, one of the drawbacks of this technique is matrix interference peaks at low masses. Metal oxide surfaces are described here for direct,
Autor:
Michael Batzle, Kent J. Voorhees, Kejing Li, Ala Bazyleva, Robert J. Evans, Casey R. McAlpin, Matthew W. Liberatore, Andrew M. Herring, Babajide Akeredolu
Publikováno v:
Energy & Fuels. 26:4445-4453
The prediction of viscosity in the extraction of heavy and viscous oil resources is essential for the economically viable production of these resources. A rheological and chemical investigation of oils from the McMurray formation produced at differen
Publikováno v:
Energy & Fuels. 25:5407-5415
Trace components present in biodiesel have been shown to contribute to the precipitation of solids at temperatures above the cloud point. These precipitates represent an operability problem for use of biodiesel in cold climates. Separation methods fo
Publikováno v:
Rapid Communications in Mass Spectrometry. 24:11-14
Bacteriophage (phage) proteins have been analyzed previously with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). However, analysis of phage major capsid proteins (MCPs) has been limited by the ability to
Publikováno v:
Rapid communications in mass spectrometry : RCM. 29(21)
Bacterial fatty acid profiling is a well-established technique for bacterial identification. Current methods involving esterification and gas chromatography/mass spectrometry (GC/MS) or matrix-assisted laser desorption/ionization (MALDI) analysis are