Carmen Gorska Putynska
The modern building industry is continually seeking materials and products that are less pollutant, stronger, more aesthetically appealing and easier to construct with. As a response to these drivers, Engineered Wood Products (EWP) have entered the c
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::eeac71764171d9bb8c6853f6c59ba5fe
https://doi.org/10.14264/uql.2020.795
https://doi.org/10.14264/uql.2020.795
Autor:
Richard Emberley, Mateo Gutierrez Gonzalez, Kathryn Humphreys, Juan P. Hidalgo, Cristian Maluk, Angela Solarte, Aaron Bolanos, Angus Law, Andrea Lucherini, Carmen Gorska Putynska, Jose L. Torero, Diana Soriguer
Publikováno v:
Emberley, R, Gorska Putynska, C, Bolanos, A, Lucherini, A, Solarte, A, Soriguer, D, Gutierrez Gonzalez, M, Humphreys, K, Hidalgo, J P, Maluk, C, Law, A & Torero-Cullen, J 2017, ' Description of small and large-scale cross laminated timber fire tests ', Fire Safety Journal, vol. 91, pp. 327-335 . https://doi.org/10.1016/j.firesaf.2017.03.024
A large-scale fire test was conducted on a compartment constructed from cross laminated timber (CLT). The internal faces of the compartment were lined with non-combustible board, with the exception of one wall and the ceiling where the CLT was expose
Publikováno v:
SGEM International Multidisciplinary Scientific GeoConference EXPO Proceedings.
The presented experimental work investigates the development of fire in a compartment made of cross laminated timber (CLT) panels and its impact on fire safety of cables. Impact of protective shielding provided by plasterboards compared to exposed pa
Publikováno v:
Fire Technology; Mar2019, Vol. 55 Issue 2, p383-386, 4p