Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Carlos Zorraquino"'
Autor:
M. Pizzichemi, L. Ferramacho, Marco Paganoni, José C. Da Silva, M. Silveira, Stefaan Tavernier, Paul Lecoq, Carlos Zorraquino, Agostino Di Francesco, T. Niknejad, G. Stringhini, Ricardo Bugalho, Etiennette Auffray, Joao Varela, C. Leong, M. Rolo, Rui Silva
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, 2017-02-11, Vol. 845
Archivo Digital UPM
Universidad Politécnica de Madrid
Archivo Digital UPM
Universidad Politécnica de Madrid
We have developed a Time-of-flight high resolution and commercially viable detector module for the application in small PET scanners. A new approach to depth of interaction (DOI) encoding with low complexity for a pixelated crystal array using a sing
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e7f21bfacb08b9789f642e48ed56f048
https://doi.org/10.1016/j.nima.2016.04.080
https://doi.org/10.1016/j.nima.2016.04.080
Autor:
Catarina Ortigao, J. Varela, Jorge A. Neves, M. Rolo, Stefaan Tavernier, Carlos Zorraquino, José Luis da Conceição Silva, Rui F. Silva, R. Bugalho, Viesturs Veckalns
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 732:607-610
The ClearPEM is a dedicated APD-based PET detector for high-resolution breast cancer imaging. The detector module is composed of 12 LYSO:Ce crystal matrices, each with 4 x 8 individual crystals (2 x 2 x 20 mm(3)) optically coupled on both ends to S85
Autor:
L. Ferramacho, R. Silva, C. Leong, Carlos Zorraquino, S. Setayeshi, R. Bugalho, T. Niknejad, M. Silveira, Joao Varela, João Carlos Silva, Stefaan Tavernier, M. Shamshirsaz, A. Di Francesco, M.D. Rolo
Publikováno v:
Journal of instrumentation, ISSN 1748-0221, 2016-12-06, Vol. 11
Archivo Digital UPM
instname
Archivo Digital UPM
instname
We have developed a highly integrated, fast and compact readout electronics for Silicon Photomultiplier (SiPM) based Time of Flight Positron Emission Tomography (TOF-PET) scanners. The readout is based on the use of TOP-PET Application Specific Integ
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::135be536f5c0f1db05ec5163d2d0b0c0
https://oa.upm.es/46268/
https://oa.upm.es/46268/
Autor:
Joao Varela, Carlos Zorraquino, Arthur W. Magill, José C. Da Silva, Rui Silva, Jorge A. Neves, Stefaan Tavernier, Catarina Ortigao, Ricardo Bugalho, Rolf Gruetter
Publikováno v:
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
We present performance results for a PET detector prototype in simultaneous operation within a 7 T MR system. The detectors are based on ClearPEM technology, a dedicated PET scanner for high-resolution breast imaging, and suitable for integration int
Autor:
T. Niknejad, Catarina Ortigao, M. Rolo, Carlos Zorraquino, José Luis da Conceição Silva, Viesturs Veckalns, Agostino Di Francesco, Jorge A. Neves, Rui F. Silva, Ricardo Bugalho, Katayoun Doroud, Joao Varela, Stefaan Tavernier
Publikováno v:
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
A compact Detector Module for Time-Of-Flight PET integrating 128 gamma-ray detection pixels of 3.5×3.5×15 mm3 LYSO crystals associated to MPPC photosensors has been developed in the framework of the EndoTOFPET-US collaboration. The module has two 6
Autor:
Carlos Zorraquino, Ricardo Bugalho, Manuel Rolo, Jose C. Silva, Viesturs Vecklans, Rui Silva, Catarina Ortigao, Jorge A. Neves, Stefaan Tavernier, Joao Varela
Publikováno v:
2014 19th IEEE-NPSS Real Time Conference.
Autor:
Viesturs Veckalns, Bugalho, R., Rui Silva, Neves, Jorge A., Stefaan Tavernier, Carlos Zorraquino, Ortigao, C., Manuel Rolo, Silva, José C., Joao Varela
Publikováno v:
CIÊNCIAVITAE
Vrije Universiteit Brussel
Vrije Universiteit Brussel
The ClearPEM is a dedicated APD-based PET detector for high-resolution breast cancer imaging. The detector module is composed of 12 LYSO:Ce crystal matrices, each with 4 x 8 individual crystals (2 x 2 x 20 mm(3)) optically coupled on both ends to S85
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::7100acff5c06bc459a9afb1fb3bb1025
https://hdl.handle.net/20.500.14017/aace4981-9539-413b-93ea-dacbc95ddf88
https://hdl.handle.net/20.500.14017/aace4981-9539-413b-93ea-dacbc95ddf88
Autor:
M. Rolo, Carlos Zorraquino, José Luis da Conceição Silva, Ricardo Bugalho, Viesturs Veckalns, Angelo Rivetti, Joao Varela, Stefaan Tavernier, Rui F. Silva, Richard Wheadon
Publikováno v:
2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).
A low power SiPM readout ASIC for Time of Flight applications, integrating signal conditioning and discrimination circuitry and high-performance TDCs for each of 64 independent channels, targeting 25 ps r.m.s r.m.s. intrinsic resolution and featuring
Publikováno v:
Geo-Congress 2013.
A large number and types of MSE (Mechanically Stabilized Earth) structures of various types have been designed and built around the world throughout the last thirty years as safe, reliable, and stable alternatives to conventional structures (e.g. cas
Publikováno v:
2012 6th European Conference on Antennas and Propagation (EUCAP).
Two Ka-Band circularly polarized multi-beam antenna systems are compared. In both cases, the antenna system is composed of a dielectric lens fed by circular waveguides terminated with small horns, but the circular polarization is achieved either by i