Publikováno v:
Medical Physics. 34:3054-3066
Conventional radiotherapy is planned using free-breathing computed tomography(CT), ignoring the motion and deformation of the anatomy from respiration. New breath-hold-synchronized, gated, and four-dimensional (4D) CT acquisition strategies are enabl
Publikováno v:
Journal of Real-Time Image Processing. 1:285-301
Minimally invasive image-guided interventions (IGIs) are time and cost efficient, minimize unintended damage to healthy tissue, and lead to faster patient recovery. One emerging trend in IGI workflow is to use volumetric imaging modalities such as lo
Publikováno v:
Medical Physics. 33:4490-4498
A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation
Autor:
Raj Shekhar, Jong-Min Song, Carlos R. Castro-Pareja, Vivek Walimbe, Jian Xin Qin, Vladimir Zagrodsky
Publikováno v:
IEEE Transactions on Medical Imaging. 24:1089-1099
Real-time three-dimensional (3-D) echocardiography is a new imaging modality that presents the unique opportunity to visualize the complex 3-D shape and motion of the left ventricle (LV) in vivo and to measure the associated global and local function
Publikováno v:
International Congress Series. 1281:435-440
The accuracy of mutual information-based registration for automatic alignment of planning CT and daily 3D ultrasound images is evaluated. The results show the importance of preprocessing both the CT and the daily 3D ultrasound images to maximize regi
Autor:
Carlos R. Castro-Pareja, Raj Shekhar
Publikováno v:
Journal of Imaging Science and Technology. 49:105-113
Autor:
Carlos R. Castro-Pareja, Jogikal M. Jagadeesh, Vivek Walimbe, Vladimir Zagrodsky, Raj Shekhar
Publikováno v:
RadioGraphics. 23:1673-1681
A generalized, accurate, automatic, retrospective method of image registration for three-dimensional images has been developed. The method is based on mutual information, a specific measure of voxel similarity, and is applicable to a wide range of im
Publikováno v:
Medical physics. 34(7)
Conventional radiotherapy is planned using free-breathing computed tomography (CT), ignoring the motion and deformation of the anatomy from respiration. New breath-hold-synchronized, gated, and four-dimensional (4D) CT acquisition strategies are enab
Autor:
R. Shekhar, Carlos R. Castro-Pareja
Publikováno v:
Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference. 2004
We present a new solution to prevent mesh folding artifacts common in free-form deformation-based nonrigid registration. Our algorithm imposes linear bounds on the search space of control point locations, thereby enabling the use of constrained optim
Publikováno v:
SPIE Proceedings.
Real-time acquisition of 3D volumes is an emerging trend in medical imaging. True real-time 3D ultrasonic imaging is particularly valuable for echocardiography and trauma imaging as well as an intraoperative imaging technique for surgical navigation.