Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Carl Geisik"'
Autor:
Thomas Zaugg, D.P. Sandoval, D. Gilpatrick, E. A. Meyer, J. Power, D. Hodgkins, Joseph D. Sherman, Gerald O. Bolme, C. Rose, G. McMichael, T. Taylor, P. Lara, Lash Hansborough, R.R. Stevens, R. Wright, M. Stettler, P. Schafstall, D. Spence, Michael E. Thuot, Carl Geisik, J.D. Schneider
Publikováno v:
Review of Scientific Instruments. 67:1296-1301
Powerful cw proton linear accelerators (100 mA at 0.5–1.0 GeV) are being proposed for spallation neutron‐source applications. A 75‐keV, 110‐mA dc proton injector using a microwave ion source is being tested for these applications. It has achi
Publikováno v:
Review of Scientific Instruments. 62:2314-2317
H− ion beams are extracted at 5–25 kV from a long, narrow slit on a Penning surface‐plasma source (the 8X source). The extraction geometry produces negligible transverse electric fields (focusing effects) along the slit length. Therefore, the i
Publikováno v:
Review of Scientific Instruments. 65:1176-1178
After developing a pulsed 8X source for H− beams, we are now testing a cooled, dc version. The design dc power density on the cathode surface is 900 W/cm2, much higher than achieved in any previously reported Penning surface‐plasma source. The so
Publikováno v:
Proceedings of International Conference on Particle Accelerators.
A pulsed 8X source was built and the H/sup -/ beam current, emittance, and power efficiency were measured. These results were promising, so a cooled, dc version designed for operation at are power levels up to 30 kW was built. Testing of the CW 8X so
Publikováno v:
Review of Scientific Instruments. 63:2723-2725
Simple analysis of the nearly-Maxwellian angular distribution of the ribbon H{sup {minus}} ions beams extracted from a long, narrow slit on the 8X source yields the H{sup {minus}} temperature, kT{sub H{minus}}. The derived kT{sub H{minus}} are 0.1--0
Autor:
Jim Porter, J. David Schneider, J.E. Stelzer, Bruce Abel, Carl Geisik, Irwin Birnbaum, Ron Heuer, H. Vernon Smith, Paul Allison, Joe Sredniawski, Stuart D. Orbesen, David Schmitt
Publikováno v:
AIP Conference Proceedings.
Using the 4X source performance and the Penning SPS scaling laws, we predicted the performance of the 8X source. A pulsed 8X source was then built and tested. After verifying the pulsed 8X source operation, especially the H− beam current, emittance
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.