Publikováno v:
IEEE Access, Vol 8, Pp 72528-72536 (2020)
Reduced-order active disturbance rejection controller (RADRC) treats the controlled plant as a cascade integral model, assuming as little information about the plant as possible. However, if more information of the plant is known, we can use this inf
Externí odkaz:
https://doaj.org/article/8467b83a3efd4be8aecfe6913731ce56
Publikováno v:
IEEE Access, Vol 8, Pp 16606-16617 (2020)
This paper investigates linear active disturbance rejection control (ADRC) for processes with time delay. In the past years several modified active disturbance rejection control methods, including Smith predictor based ADRC (SP-ADRC), predictor obser
Externí odkaz:
https://doaj.org/article/c815165b5d0f408ebc4389a8ac104d86
Publikováno v:
IEEE Transactions on Industrial Electronics. 68:6217-6226
Linear active disturbance rejection control (LADRC) takes the controlled plant as a cascaded integral model and treats all other plant information and external disturbances as a generalized disturbance, and uses an linear extended state observer (ESO
Publikováno v:
Journal of the Franklin Institute. 358:339-362
To reduce the phase lag introduced by extended state observer (ESO), an reduced-order active disturbance rejection control (RADRC) method is recommended. This paper investigates the structure and parameter tuning of RADRC. Firstly, it is shown that R
Publikováno v:
IEEE Access, Vol 8, Pp 16606-16617 (2020)
This paper investigates linear active disturbance rejection control (ADRC) for processes with time delay. In the past years several modified active disturbance rejection control methods, including Smith predictor based ADRC (SP-ADRC), predictor obser
Publikováno v:
IET Generation, Transmission & Distribution. 12:1397-1403
A decentralised load frequency control (LFC) for multi-area power systems with communication delays is studied. Active disturbance rejection control (ADRC) method is adopted to handle the communication delays. First the conventional ADRC is tuned via
Publikováno v:
ISA Transactions. 65:384-393
Linear active disturbance rejection control (ADRC) is known for its simplicity and its performance in disturbance attenuation. Currently, tuning of linear ADRC (LADRC) is via the bandwidth idea. In this paper, tuning of LADRC with known plant informa
Publikováno v:
ISA transactions. 71(Pt 2)
Active disturbance rejection control (ADRC) treats the external disturbance and internal uncertainties as a general disturbance, and uses an extended state observer (ESO) to estimate it in real-time and feeds it back in the control loop, thus can ach
Publikováno v:
ACC
Linear active disturbance rejection control (ADRC) is known for its simplicity and its performance in disturbance attenuation. Currently, tuning of linear ADRC is via the bandwidth idea proposed in [1]. It is first shown that there are some limitatio
Publikováno v:
2016 11th International Forum on Strategic Technology (IFOST).
This paper focuses on Model Predictive Controller for nonlinear drum boiler, which was presented in Morilla (2012) as Benchmark PID problem. The MPC controller that based on state-space form was proposed. Simulation results of the proposed controller