Zobrazeno 1 - 10
of 32
pro vyhledávání: '"Caibo Liao"'
Publikováno v:
Case Studies in Thermal Engineering, Vol 64, Iss , Pp 105554- (2024)
Hotspot temperature is a key factor affecting the safe operation for power equipment like reactor. The different distribution of the magnetic field in the iron-core and windings results in non-uniform distribution of the electromagnetic losses. Howev
Externí odkaz:
https://doaj.org/article/bc136cf452e843b2859511d6492b007b
Publikováno v:
Case Studies in Thermal Engineering, Vol 49, Iss , Pp 103324- (2023)
The smoke and poisonous gas produced during combustion is one of the direct hazards of cable fire. For power cables laid vertically in the cable shaft of high-rise buildings, the chimney effect will speed up the spread and expand the harm of cable fi
Externí odkaz:
https://doaj.org/article/162f9158196b447da0b4ec9e8e4f9742
Publikováno v:
IET Generation, Transmission & Distribution, Vol 16, Iss 5, Pp 869-881 (2022)
Abstract Efficient bird damage prevention of transmission lines is a long‐term challenge for power grid operation and maintenance. An approach combined lightweight convolutional neural network (CNN), image processing and object detection is present
Externí odkaz:
https://doaj.org/article/4b5c160334d94a9bac268326b9f5dc6c
Publikováno v:
IET Electric Power Applications, Vol 16, Iss 3, Pp 350-361 (2022)
Abstract A high voltage current transformer of the inverted type is a commonly used measurement equipment in power grids. The thermal behaviour of the current transformer has a significant impact on its operating conditions and is directly related to
Externí odkaz:
https://doaj.org/article/74c8a600a6194da1a12d277571f8f237
Publikováno v:
Applied Sciences, Vol 12, Iss 16, p 8360 (2022)
The correct identification of partial discharge types is of great significance to the stable operation of GIS. In order to improve the recognition accuracy and result of partial discharge, and to meet the requirements of real-time monitoring of GIS e
Externí odkaz:
https://doaj.org/article/9ec082a6ef7546228c200dd7b9847006
Publikováno v:
Applied Sciences, Vol 12, Iss 3, p 1207 (2022)
Defective insulators seriously threaten the safe operation of transmission lines. This paper proposes an insulator defect detection method based on an improved YOLOv4 algorithm. An insulator image sample set was established according to the aerial im
Externí odkaz:
https://doaj.org/article/0d83042ee01a42d3b977d4bd96c84a36
Publikováno v:
IEEE Transactions on Power Delivery. 38:1329-1340
Publikováno v:
Journal of Electrical Engineering & Technology. 18:2447-2456
Publikováno v:
IEEJ Transactions on Electrical and Electronic Engineering. 17:1728-1737
Publikováno v:
IET Electric Power Applications, Vol 16, Iss 3, Pp 350-361 (2022)
A high voltage current transformer of the inverted type is a commonly used measurement equipment in power grids. The thermal behaviour of the current transformer has a significant impact on its operating conditions and is directly related to its serv