Zobrazeno 1 - 10
of 42
pro vyhledávání: '"C.E. Nockolds"'
Autor:
Matthew R. Phillips, C.E. Nockolds, Guy Remond, Claude Roques-Carmes, Michel Fialin, Robert L. Myklebust
Publikováno v:
Journal of Research of the National Institute of Standards and Technology
Line shapes of atomic lines and soft x-ray emission bands measured with a wavelength dispersive spectrometer (WDS) with the Electron Probe Micro Analyzer (EPMA) are reviewed. Least square fitting to pseudo-Voigt profiles of the digitally measured spe
Publikováno v:
Scanning. 24:171-174
A simple method is described to determine the effective gas path length when incident electrons scatter in the gas above the specimen. This method is based on the measurement of a characteristic x-ray line emitted from a region close to the incident
The influence of codopants and fabrication conditions on germanium defects in optical fiber preforms
Publikováno v:
IEEE Photonics Technology Letters. 4:43-46
The GeE' defect concentration in MCVD germanosilicate preforms, as measured by cathodoluminescence profiles, is dramatically reduced by the addition of phosphorus as a codopant. The GeE' concentration is increased by using higher deposition temperatu
Publikováno v:
Micron and Microscopica Acta. 23:303-314
Cathodoluminescence (CL) in the scanning electron microscope has been applied to the analysis of germanosilicate preforms and optical fibres prepared by the MCVD process. While generally sensitive to the distribution of dopants, CL is an even more se
Autor:
C.E. Nockolds, Brendan Griffin
Publikováno v:
Scanning. 13:307-312
A detailed investigation of the relationship between the mean atomic number and the intensity of high energy continuum radiation has verified earlier studies in defining a linear relationship. Corrections for matrix effects on the continuum intensity
Autor:
Brendan Griffin, C.E. Nockolds
Publikováno v:
Microscopy and Microanalysis. 11
Publikováno v:
Archives of oral biology. 49(5)
The deterioration of the mechanical properties of carious dentine was assumed to be associated with the decrease in mineral content due to the carious process. This study aimed to compare the mechanical properties of carious dentine studied by an ult
Publikováno v:
Archives of oral biology. 49(2)
Backscattered electron-scanning electron microscope (BSE-SEM) imaging has been recommended as a reliable tool to quantify the mineralisation state of calcified tissues and is commonly used in bone studies. The aim of this study is to investigate the
Publikováno v:
Microscopy and Microanalysis. 8:1496-1497
Publikováno v:
Microscopy and Microanalysis. 7:708-709
X-ray microanalysis of any type of specimen in its natural state without the use of conventional SEM specimen preparation techniques has immense potential in a wide range 'of scientific and industrial applications. This capability would be particular