Zobrazeno 1 - 10
of 102
pro vyhledávání: '"C. Shiach"'
Autor:
Stirling Bryan, Gualtiero Palareti, C. Shiach, Alexander G.G. Turpie, F. J. M. Van Der Meer, Marco Moia, M. Keown, Leon Poller, Sue Jowett, Saied Ibrahim, Gordon D.O. Lowe, Jørgen Jespersen, A. M. H. P. Van Den Besselaar, Armando Tripodi
Publikováno v:
Journal of Thrombosis and Haemostasis. 7:1482-1490
BACKGROUND: Increased demand for oral anticoagulation has resulted in wider adoption of computer-assisted dosing in anticoagulant clinics. An economic evaluation has been performed to investigate the cost-effectiveness of computer-assisted dosing in
Autor:
Mario von Depka, Bernard Boneu, Johan Frieling, Marie Helene Horellou, R. Campbell Tait, Don W. Shaffer, Laura J. Bonfiglio, Robert Klamroth, Carl-Erik Dempfle, Andreas Tiede, John Lazarchick, Andrew D Mumford, C. Shiach, Jacqueline Conard, Francesco Baudo, Sam Schulman
Publikováno v:
Thrombosis and Haemostasis. 99:616-622
SummaryDuring surgery and childbirth, patients with hereditary antithrombin (AT) deficiency are at high risk for thrombosis,and heparin prophylaxis may not be sufficiently efficacious. In these patients, exogenous AT may be used in association with h
Autor:
Gordon D.O. Lowe, Saied Ibrahim, F. J. M. Van Der Meer, C. Shiach, Chris Roberts, A. M. H. P. Van Den Besselaar, M. Keown, G. Palareti, Leon Poller, J. Jespersen, Armando Tripodi, Stirling Bryan
Publikováno v:
University of Southern Denmark
Poller, L, Keown, M, Ibrahim, S, van den Besselaar, AMHP, Bryan, S, van der Meer, FJM, Palareti, G, Roberts, C, Shiach C, C, Tripodi, A, Jespersen, J & Lowe, GDO 2007, ' Cost-effectiveness of computer-assisted anticoagulant dosage clinical study ', Journal of Thrombosis and Haemostasis, vol. 5, no. Suppl. 2, pp. O-T-054 .
Poller, L, Keown, M, Ibrahim, S, van den Besselaar, AMHP, Bryan, S, van der Meer, FJM, Palareti, G, Roberts, C, Shiach C, C, Tripodi, A, Jespersen, J & Lowe, GDO 2007, ' Cost-effectiveness of computer-assisted anticoagulant dosage clinical study ', Journal of Thrombosis and Haemostasis, vol. 5, no. Suppl. 2, pp. O-T-054 .
Autor:
N. Chauhan, M. Keown, Jørgen Jespersen, Anton M.H.P. van den Besselaar, Armando Tripodi, C. Shiach, Leon Poller
Publikováno v:
Clinical Chemistry. 50:537-544
Background: International Normalized Ratios (INRs) for prothrombin time obtained with the CoaguChek Mini and TAS (RapidPointCoag) PT-NC systems are markedly different and also differ from the “true” INR. There is therefore a need for local qualit
Autor:
Jørgen Jespersen, N. Chauhan, C. Shiach, Anton M.H.P. van den Besselaar, M. Keown, Armando Tripodi, Leon Poller
Publikováno v:
British Journal of Haematology. 122:944-949
The international normalized ratio (INR) on two widely used point-of-care test (POCT) prothrombin time (PT) monitors (CoaguChek Mini and TAS PT-NC) differed considerably and also differed from the 'true' INR obtained on the same samples using a manua
Autor:
Armando Tripodi, N. Chauhan, Jørgen Jespersen, A. M. H. P. Van Den Besselaar, M. Keown, C. Shiach, Leon Poller
Publikováno v:
Journal of Thrombosis and Haemostasis. 1:766-772
Summary. Previously, the attempt to simplify the International Sensitivity Index (ISI) calibration of the CoaguChek Mini whole blood point-of-care test prothrombin time (PT) monitor system was successful using lyophilized plasmas from coumarin-treate
Autor:
Jørgen Jespersen, Armando Tripodi, Anton M.H.P. van den Besselaar, N. Chauhan, M. Keown, C. Shiach, Leon Poller
Publikováno v:
American Journal of Clinical Pathology. 119:232-240
International sensitivity index (ISI) calibration of whole blood prothrombin time (PT) monitors is too complex. We previously simplified the method by using European Concerted Action on Anticoagulation (ECAA) lyophilized plasma samples with the TAS P
Autor:
Armando Tripodi, N. Chauhan, Jørgen Jespersen, Leon Poller, C. Shiach, A. M. H. P. Van Den Besselaar, M. Keown
Publikováno v:
Journal of Clinical Pathology. 56:114-119
Aims: The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The p
Publikováno v:
British Journal of Haematology. 119:370-375
The success in achieving therapeutic international normalized ratio (INR) targets in the control of warfarin using a whole-blood point-of-care testing (POCT) monitor (CoaguChek) in a community clinic was compared with hospital laboratory coagulometer
Autor:
C. Shiach, M. Keown, Jørgen Jespersen, Leon Poller, A. M. H. P. Van Den Besselaar, N. Chauhan, Armando Tripodi
Publikováno v:
Thrombosis Research. 107:61-66
Introduction: Prothrombin time (PT) test systems require multicentre calibration for reliable International Sensitivity Index (ISI). Multicentre calibration of CoaguChek Mini and TAS PT-NC point-of-care test (POCT) systems is less precise than conven