Zobrazeno 1 - 10
of 458
pro vyhledávání: '"C. M. Dozier"'
Publikováno v:
Advances in X-ray Analysis. 39:73-79
Large area, parallel beams of x-rays are potentially useful in many diffraction, imaging and other x-ray analysis applications. Diffraction, in typical experiments, uses only a small portion of the incident beam that is within a limited “rocking cu
Publikováno v:
Advances in X-ray Analysis. 37:499-506
Capillary collimators have found a number of uses in fluorescence, diffraction and other x-ray fields. Most of these applications are realized with single, straight glass capillaries. Focussing of synchrotron x-radiation beams has been shown with tap
Publikováno v:
Review of Scientific Instruments. 62:982-985
Small alignment errors of right‐angle linkage monochromators typical to many x‐ray absorption fine structure beamlines can cause significant errors in the energy calibrations. A 1° misalignment produces errors greater than 1 keV over the hard x
Publikováno v:
Advances in X-ray Analysis. 35:401-405
The design, construction and operation of toroidal focusing X-ray monochromators have been described in detail by Marcus, et al. (1980) and by Furnas, et al. (1982), Marcus, et al. used 100 mechanically damaged, singly bent LiF (200) (2d = 4.02 Å) s
Publikováno v:
IEEE Transactions on Nuclear Science. 37:1677-1681
Fast measurements of channel current versus gate voltage (I-V) were performed on irradiated MOSFETs as a function of time and temperature after pulsed proton irradiation. Stretchout of the I-V curves due to lateral nonuniformities (LNUs) in the hole
Autor:
W. M. Gibson, V. E. Kovantsev, K. Umezawa, C. M. Dozier, J. V. Gilfrich, J. P. Kirkland, Qi‐Fan Xiao
Publikováno v:
Review of Scientific Instruments. 66:1410-1412
A wavelength‐dispersive x‐ray fluorescence detector system has been developed that can be used to discriminate fluorescent photon energies for practically any incident flux. The system uses a Kumakhov polycapillary lens to collimate fluorescent p
Publikováno v:
Advances in X-Ray Analysis ISBN: 9780306458033
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::f79ab41ebc6b4388d69ee298fbc49e35
https://doi.org/10.1007/978-1-4615-5377-9_88
https://doi.org/10.1007/978-1-4615-5377-9_88
Publikováno v:
Advances in X-Ray Analysis ISBN: 9780306458033
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::536280bee95139216d0254031a3e73b8
https://doi.org/10.1007/978-1-4615-5377-9_9
https://doi.org/10.1007/978-1-4615-5377-9_9
New experimental evidence is presented that supports a model that assumes two distinguishable types of positive oxide charge following x-irradiation. Two new experiments have been performed designed to separate the annealing properties of the two typ
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9ce28d18f298f96fa883f02813557198
https://zenodo.org/record/1261404
https://zenodo.org/record/1261404
Publikováno v:
Advances in X-Ray Analysis ISBN: 9781461360773
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2d89a40fd0d9e9b023d346252bd34c06
https://doi.org/10.1007/978-1-4615-2528-8_61
https://doi.org/10.1007/978-1-4615-2528-8_61