Zobrazeno 1 - 10
of 30
pro vyhledávání: '"C. C. St. Pierre"'
Publikováno v:
Canadian Journal of Civil Engineering. 20:725-735
Horseradish peroxidase enzyme (HRP), once activated by hydrogen peroxide, initiates the oxidation of a wide variety of aromatic compounds. Reaction products undergo a non-enzymatic polymerization to form water insoluble aggregates which are readily s
Publikováno v:
Water Science and Technology. 25:157-164
Horseradish peroxidase enzyme (HRP) catalyzes the oxidation of aromatic compounds by hydrogen peroxide. Reaction products undergo a non-enzymatic polymerization to form water insoluble aggregates which readily separate from solution. The capabilities
Publikováno v:
Journal of Canadian Petroleum Technology. 30
Abstract The design of an all- Teflon impinge train, suitable for the sampling of trace elements from high-pressure gas process streams, is described. The method was used to sample streams that might be diverted to flare slacks at two sour gas plants
Publikováno v:
The Canadian Journal of Chemical Engineering. 61:504-508
The maximum centreline penetrations, l**, of cross-current liquid jets in a Venturi scrubber were measured for orifice diameters, d, of 1.397, 2.108, 2.565 and 3.860 mm. The data are correlated by for the range of conditions, 36 ≤ gas throat veloci
Publikováno v:
Industrial & Engineering Chemistry Fundamentals. 23:303-308
Liquid core and wall film flow rates have been measured in a pilot plant scale Venturi scrubber of Pease-Anthony design for liquid-to-gas flow ratios varying between 3 and 14 U.S. gal of H/sub 2/O/1000 SCF of air. The gas throat velocities were 150,
Publikováno v:
Atmospheric Environment (1967). 17:139-143
A technique for the determination of odor thresholds, that accounts for the possibility of correct responses from panelists without true discrimination, is proposed. An existing model is examined for its applicability to forced binary tests. In addit
Publikováno v:
Environmental Progress. 5:240-244
Dynamic dilution olfactometers provide a range of odor dilutions for presentation to panelists. Reliable odor thresholds of source emissions can be evaluated consistently only if the unknown odor thresholds fall in the middle of the dilution range of
Publikováno v:
Atmospheric Environment (1967). 20:2459-2464
Several methods of data analysis used for the evaluation of odor detection thresholds have been examined through application to two samples of n-butanol. Panels of seven-ten people, working with a six level, IITRI, ternary forced choice olfactometer,
Publikováno v:
AIChE Journal. 31:1947-1958
An annular flow pressure drop model has been developed and compared with experimental data obtained on a pilot-plant-size Pease-Anthony-type venturi scrubber. Droplet and film accelerations as well as wall friction, based on the two-phase Lockhart-Ma
Publikováno v:
AIChE Journal. 15:51-56