Ł. Kocewiak, R. Blasco-Gimenez, C. Buchhagen, J. B. Kwon, M. Larsson, A. S. Trevisan, Y. Sun, X. Wang
Publikováno v:
20th International Workshop on Large-Scale Integration of Wind Power into Power Systems as well as on Transmission Networks for Offshore Wind Power Plants (WIW 2021).
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
2013 IEEE Power & Energy Society General Meeting.
The use of power electronics and other assets with a nonlinear impedance characteristic causes harmonics in the electrical grid which should be monitored to keep the power quality at a high level. System operators connect their secondary equipment ma
Publikováno v:
2013 IEEE Power & Energy Society General Meeting.
Common inductive voltage transformers have natural frequencies in the range of some thousand hertz. Thus, their use for harmonic monitoring has to be assessed. By doing some changes in the design of voltage transformers, it is possible to compensate
Publikováno v:
2012 IEEE International Conference on Power System Technology (POWERCON).
Up till now inductive voltage transformers are only suitable for measuring harmonics if high measurement errors are acceptable. However, as monitoring frequency harmonics becomes more important, the design of inductive voltage transformers needs to b
Publikováno v:
2012 IEEE International Energy Conference and Exhibition (ENERGYCON).
Inductive voltage transformers in the electrical grid are normally used for frequencies of 50/60 Hz. This is reasonable, because they have natural frequencies which lie considerable above 50/60 Hz. On a 20 kV voltage transformer the first natural res
Publikováno v:
PES T&D 2012.
In many cases, the increasing load and the growing proportion of injected power from distributed energy generation results in the violation of voltage constraints in low voltage distribution grid. As an alternative to additional cables or substations
Publikováno v:
PES T&D 2012.
To increase the linear frequency range of inductive medium voltage transformers, the calculation of its frequency response will be the first step. For this several capacitances have to be known, such as the layer, the ground and the front part capaci