Zobrazeno 1 - 10
of 18
pro vyhledávání: '"C L, Byrd"'
Publikováno v:
Journal of bacteriology. 54(1)
Publikováno v:
Journal of bacteriology. 53(3)
Autor:
C, Kennergren, R H, Schaerf, T D, Sellers, B L, Wilkoff, C L, Byrd, G F, Tyres, S, Coe, C W, Coates, C, Reiser
Publikováno v:
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 4(4)
Extraction of chronically implanted pacing and defibrillator leads is facilitated by using specialized locking stylets placed in the lead to allow application of traction and to stabilize the lead during sheath dissection of fibrotic tissue. We repor
Autor:
C J, Love, B L, Wilkoff, C L, Byrd, P H, Belott, J A, Brinker, N E, Fearnot, R A, Friedman, S, Furman, L B, Goode, D L, Hayes, D T, Kawanishi, V, Parsonnet, C, Reiser, H J, Van Zandt
Publikováno v:
Pacing and clinical electrophysiology : PACE. 23(4 Pt 1)
The procedure of lead removal has recently matured into a definable, teachable art with its own specific tools and techniques. It is now time to recognize and formalize the practice of lead removal according to the current methods of medicine and the
Autor:
C L, Byrd, B L, Wilkoff, C J, Love, T D, Sellers, K T, Turk, R, Reeves, R, Young, B, Crevey, S P, Kutalek, R, Freedman, R, Friedman, J, Trantham, M, Watts, J, Schutzman, J, Oren, J, Wilson, F, Gold, N E, Fearnot, H J, Van Zandt
Publikováno v:
Pacing and clinical electrophysiology : PACE. 22(9)
Of the 400,000-500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved
Publikováno v:
Pacing and clinical electrophysiology : PACE. 17(11 Pt 2)
From December 1988 to April 1994, the extraction of 2,195 intravascular pacing leads from 1,299 patients was attempted at 193 centers. Indications were: infection (54%, including 10% septicemia), pacemaker reoperation with removal of nonfunctional or
Publikováno v:
The Journal of thoracic and cardiovascular surgery. 101(6)
Intravascular techniques were used to extract 226 leads from 124 patients. Indications for lead extraction were life-threatening septicemia (30%), complications of free-floating leads (2%), abandonment of pockets (40%), and replacement of malfunction
Autor:
L B, Goode, C L, Byrd, B L, Wilkoff, J M, Clarke, J M, Fontaine, N E, Fearnot, H J, Smith, F J, Shipko
Publikováno v:
Biomedical instrumentationtechnology. 25(1)
Transvenous removal of chronic pacing leads was attempted using a special locking stylet and dilator sheaths. In five initial cases, three of seven leads were infected; six of seven leads were removed. The stylet was inserted into the conductor lumen
Publikováno v:
Annals of Surgery. 176:757-760
Publikováno v:
Pacing and clinical electrophysiology : PACE. 6(5 Pt 1)
A total of 905 unipolar polyurethane pacing leads have been implanted by the first author's group, between April 1978 and February 1982, with a mean implant of 1.4 years. Twelve leads were explanted and analyzed. Eleven of the explanted leads exhibit