Zobrazeno 1 - 10
of 24
pro vyhledávání: '"Byung Heon Ahn"'
Publikováno v:
Korean Journal of Ophthalmology. 37:53-61
Purpose: To investigate whether postoperative filtering bleb size affects the surgical outcome after trabeculectomy.Methods: In this study, we retrospectively reviewed 145 medically uncontrolled glaucoma patients with intraocular pressure (IOP) value
Publikováno v:
Journal of the Korean Ophthalmological Society. 62:1570-1574
Purpose: To report a case of late-onset bleb-associated endophthalmitis caused by streptococcus cristatus (S. cristatus) after trabeculectomy.Case summary: A 59-year-old woman presented with left ocular pain and visual disturbance. She had undergone
Publikováno v:
Graefe's Archive for Clinical and Experimental Ophthalmology. 255:163-169
To evaluate the safety and efficacy of a novel membrane-tube (MT)-type glaucoma shunt device for refractory glaucoma surgery. The device consists of an expanded polytetrafluoroethylene membranous reservoir, as well as a silicone tube (300-μm externa
Publikováno v:
Clinical & Experimental Ophthalmology. 44:776-782
BACKGROUND The background of this study is to introduce the surgical technique and outcomes of a novel membrane-tube (MT) type glaucoma shunt device (MicroMT), which was developed to achieve safer and more predictable intraocular pressure (IOP) contr
Purpose: To investigate the outflow characteristics of silicone tubes with intraluminal stents used in membrane-tube (MT) type glaucoma shunt devices (MT-device). Methods: The silicone tubes used in MicroMT (internal diameter of 100 µm with 7-0 nylo
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0ea645d277f7c5f9237fb1a422470b00
https://doi.org/10.21203/rs.2.189/v1
https://doi.org/10.21203/rs.2.189/v1
Autor:
Olusola Olawoye, Adeyinka O. Ashaye, Young Hoon Hwang, Jong Chul Han, Tarela F. Sarimiye, Byung Heon Ahn
Publikováno v:
Clinical Ophthalmology (Auckland, N.Z.)
Olusola Olawoye,1,2 Tarela Sarimiye,1,2 Adeyinka Ashaye,1,2 Young Hoon Hwang,3 Jong Chul Han,4 Byung Heon Ahn3 1Department of Ophthalmology, College of Medicine, University of Ibadan, 2Department of Ophthalmology, University College Hospital, Ibadan,
Autor:
Kwan Bok Lee, Young Cheol Yoo, Mijin Kim, Jae Keun Chung, Byung Heon Ahn, Young Hoon Hwang, Jong Jin Jung, Jae Min Wi
Publikováno v:
Journal of cataract and refractive surgery. 44(8)
Purpose To compare long-term postoperative refractive outcomes between phacotrabeculectomy and phacoemulsification, both with posterior chamber intraocular lens implantation. Setting Department of Ophthalmology, Konyang University, Kim's Eye Hospital
Publikováno v:
Current eye research. 42(6)
Purpose: To evaluate the safety and efficacy of a membrane-tube-type glaucoma shunt device (MT-device), which was developed to control intraocular pressure (IOP) with a lower chance of complications than conventional glaucoma surgery, in a rabbit mod
Autor:
Byung-Heon Ahn
Publikováno v:
The Korean Journal of Dance Studies. 51:49-67
Publikováno v:
Clinicalexperimental ophthalmology. 44(9)
The background of this study is to introduce the surgical technique and outcomes of a novel membrane-tube (MT) type glaucoma shunt device (MicroMT), which was developed to achieve safer and more predictable intraocular pressure (IOP) control compared