Zobrazeno 1 - 10
of 38
pro vyhledávání: '"Bruno Guerard"'
Autor:
Bruno Guerard, Martin Platz, Sylvain Cuccaro, James Spedding, Jerome Pentenero, Adeline Robert, Andrew Berry, J. C. Buffet, Damien Roulier, Luis Abuel, Julien Marchal, Paolo Mutti, Patrick van-Esch, Friedl Bartsch, Stephen A. Holt, Kevin Ollivier
Publikováno v:
Journal of Neutron Research. 23:53-67
A detector upgrade was carried out on the PLATYPUS instrument dedicated to neutron reflectometry at the Australian Nuclear Science and Technology Organisation (ANSTO). The new detector, developed in the framework of a research collaboration between t
Autor:
Karl Zeitelhack, Susann Schmidt, L. Robinson, Carina Höglund, L.M.S. Margato, A. Blanco, A. Morozov, Bruno Guerard, Richard Hall-Wilton, A. Mangiarotti, P. Fonte, F.A.F. Fraga
Publikováno v:
Journal of Instrumentation
Journal of Instrumentation, IOP Publishing, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
JINST
JINST, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
Journal of Instrumentation, IOP Publishing, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
JINST
JINST, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::600f400f6c1e4c4021692db054d81cd1
http://arxiv.org/abs/1809.09677
http://arxiv.org/abs/1809.09677
Autor:
S. M. Everett, I. Lopez-Higuera, F. Issa, Jens Birch, Anton Khaplanov, Kenneth W. Herwig, J.-F. Clergeau, R. Bebb, Pascale P. Deen, I. Iruretagoiena, Carina Höglund, F. Piscitelli, Jens Jensen, Bruno Guerard, Oliver Kirstein, I. Stefanescu, Georg Ehlers, Susann Schmidt, Richard Hall-Wilton, P. Van Esch, Linda Robinson, J. C. Buffet, T. Bryś, M. Anastasopoulos, Lars Hultman, K. Berry
Publikováno v:
JINST
JINST, 2017, 12 (04), pp.P04030. 〈10.1088/1748-0221/12/04/P04030〉
JINST, 2017, 12 (04), pp.P04030. ⟨10.1088/1748-0221/12/04/P04030⟩
'Journal of Instrumentation ', vol: 12, pages: P04030-1-P04030-31 (2017)
Journal of Instrumentation
JINST, 2017, 12 (04), pp.P04030. 〈10.1088/1748-0221/12/04/P04030〉
JINST, 2017, 12 (04), pp.P04030. ⟨10.1088/1748-0221/12/04/P04030⟩
'Journal of Instrumentation ', vol: 12, pages: P04030-1-P04030-31 (2017)
Journal of Instrumentation
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopp
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::265012b7a1b47791fe4e7934fab6391b
http://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-30963
http://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-30963
Autor:
Bruno Guerard, P. Geltenbort
Publikováno v:
Neutron News. 30:19-19
Anton Oed, a passionate inventor and a source of inspiration for many of us today, passed away on September 30, 2018. His introduction of Micro-Strip Gas Chambers (MSGCs) at the Institut Laue-Lange...
Autor:
Jens Jensen, P. Van Esch, J. C. Buffet, Jens Birch, C. Vettier, Ken Haste Andersen, Lars Hultman, F. Piscitelli, Bruno Guerard, Richard Hall-Wilton, Oliver Kirstein, T. Bigault, Anton Khaplanov, J. Correa, Carina Höglund
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 720:116-121
He-3 was a popular material in neutrons detectors until its availability dropped drastically in 2008. The development of techniques based on alternative convertors is now of high priority for neutron research institutes. Thin films of B-10 or (B4C)-B
Autor:
J. Correa, Jens Birch, F. Piscitelli, Bruno Guerard, Lars Hultman, Richard Hall-Wilton, Anton Khaplanov, P. van Esch, Carina Höglund, J. C. Buffet
Publikováno v:
IEEE Transactions on Nuclear Science. 60:871-878
Despite its present shortage, 3He continues to be the most common neutron converter for detectors in neutron scattering science. However, it is obvious that the development of large area neutron detectors based on alternative neutron converters is ra
Autor:
T. Bigault, P. Van Esch, Richard Hall-Wilton, Lars Hultman, F. Piscitelli, Carina Höglund, Jens Birch, Bruno Guerard, Anton Khaplanov, J. Correa, J. C. Buffet
Publikováno v:
Neutron News. 23:20-25
10B films have been studied as neutron convertors in semi-conductors [1], and in different types of gas proportional counters for neutron scattering applications: for example in [2] the detector is...
Publikováno v:
Neutron News. 23:5-9
Autor:
Ken Haste Andersen, P. Geltenbort, Toshiji Kanaya, Shane J. Kennedy, Bruno Guerard, John M. Carpenter, Giuliana Manzin, Kenji Mishima, Hiromu Tongu, Katsuya Hirota, Masaaki Kitaguchi, Masahiro Hino, M. Ichikawa, Masako Yamada, Norifumi L. Yamada, Yoshihisa Iwashita, M. Bleuel, Jyotsana Lal, Hirohiko M. Shimizu
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 634:S156-S160
We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5 × 10 4 T / m 2 ⩽ g
Autor:
A. Morozov, S.T.G. Fetal, F.A.F. Fraga, Bruno Guerard, L.M.S. Margato, M.M.F.R. Fraga, L. Pereira, G. Manzin
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 628:360-363
The effect of an electric field on the primary scintillation from CF4 in the ultraviolet and visible wavelength regions (200–800 nm) is reported. The study was performed in the pressure range from 1 to 5 bar and at electric fields of up to 2 kV/cm.