Zobrazeno 1 - 10
of 53
pro vyhledávání: '"Bruce R. Line"'
Autor:
Tomika Coleman, Sergei Bakhlanov, Mark P. Borgman, Nikolai Marchenkov, Bruce R. Line, Michael K. Schultz
Publikováno v:
Applied Radiation and Isotopes. 65:784-792
Radionuclidic impurities of (210)Po prepared by neutron irradiation of (209)Bi via the (209)Bi(n,gamma)(210)Bi reaction were investigated. Following irradiation and ingrowth, a pure (210)Po solution was obtained by sublimation and dissolution. Result
Publikováno v:
Current Pharmaceutical Design. 12:4729-4749
Several nanoscale carriers (nanoparticles, liposomes, water-soluble polymers, micelles and dendrimers) have been developed for targeted delivery of cancer diagnostic and therapeutic agents. These carriers can selectively target cancer sites and carry
Autor:
Hamidreza Ghandehari, Amitava Mitra, Anjan Nan, Bruce R. Line, Edwina Mcneill, Justin Mulholland
Publikováno v:
Pharmaceutical Research. 21:1153-1159
To synthesize novel technetium-99m (99mTc)-labeled N-(2-hydroxypropyl) methacrylamide (HPMA) copolymers and characterize the effect of charge and molecular weight on their biodistribution in SCID mice.Electronegative and neutral 7-kDa, 21-kDa, and 70
Publikováno v:
Applied Radiology. :9-20
Autor:
Charles S. White, Bruce R. Line
Publikováno v:
Current Treatment Options in Oncology. 5:63-73
The dissemination of positron emission tomography (PET) technology has enabled a functional approach to the evaluation of lung cancer that complements the anatomic assessment provided by chest radiography, computed tomography (CT) scanning, and magne
Autor:
Andrew S. Kennedy, Cedric X. Yu, Gregory D. Sackett, Zong J. Cao, Martin A. Lodge, Mehrdad Sarfaraz, Bruce R. Line, David A. Van Echo, Ravi Murthy
Publikováno v:
Medical Physics. 30:199-203
Administration of yttrium-90 microspheres via the hepatic artery is an attractive approach to selectively delivertherapeuticdoses of radiation to livermalignancies. This procedure allows deliveringradiation absorbed doses in excess of 100 Gy to the t
Publikováno v:
Applied Radiology. :9-17
Autor:
Bruce R. Line
Publikováno v:
Seminars in Nuclear Medicine. 31:90-101
Lower-limb deep venous thrombosis (DVT) affects between 1% to 2% of hospitalized patients. These thrombi disrupt the vascular integrity of the lower limbs and are the source of emboli that kill approximately 200,000 patients each year in the United S
Autor:
Bruce R. Line, William A. Wegener, Bruce J. Barron, David C. Seldin, Aldo N. Serafini, Cynthia L. Sullivan, Lamk K. Lamki, David M. Goldenberg, Hani Abdel-Nabi
Publikováno v:
Cancer. 89:104-115
BACKGROUND An adjunctive noninvasive test that is predictable and highly specific for breast carcinoma would complement the high false-positive rate of mammography in certain patients. METHODS This prospective, multicenter study evaluated the accurac
Autor:
Richard John Dansereau, Pirow J. Bekker, Bruce R. Line, Raymond N. Dansereau, Daniel P. Healy
Publikováno v:
International Journal of Pharmaceutics. 153:159-166
The comparative in-vivo disintegration, gastric emptying and bioavailability of 41 mg radiolabeled riboflavin 5′-phosphate sodium capsules administered as a single hard gelatin capsule or as four capsules was evaluated in human subjects. A total of