Zobrazeno 1 - 10
of 29
pro vyhledávání: '"Bruce Hopenfeld"'
Autor:
Bruce Hopenfeld
BackgroundThe MIT-BIH Noise Stress Test Database (NSTDB) is a publicly available resource for testing QRS detection algorithms. Serial QRS detection algorithms applied to the NSTDB have apparently failed to detect the presence of a possible heartbeat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::69d3cc2daacae5f8e815c4f1eb67d83f
https://doi.org/10.1101/2022.10.18.512701
https://doi.org/10.1101/2022.10.18.512701
Autor:
Bruce Hopenfeld
BackgroundIn some cases, the fetal electrocardiogram (ECG) has a relatively low signal to noise ratio. Much of the literature pertaining to fetal ECG processing focuses on methods for separating the fetal ECG from the maternal ECG rather than detecti
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5704513bd74b027d6996d03ca9ce3e9a
https://doi.org/10.1101/2022.08.29.505738
https://doi.org/10.1101/2022.08.29.505738
Autor:
Bruce Hopenfeld
BackgroundObtaining reliable rate heart estimates from waist based electrocardiograms (ECGs) poses a very challenging problem due to the presence of extreme motion artifacts. The literature reveals few, if any, attempts to apply motion artifact cance
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::16ba888490ea79d45d3b8985a62a73d2
https://doi.org/10.1101/2022.01.07.475456
https://doi.org/10.1101/2022.01.07.475456
Autor:
Bruce Hopenfeld
A highly constrained temporal pattern search (“TEPS”) based multiple channel heartbeat detector is described. TEPS generates sequences of peaks and statistically scores them according to: 1) peak time coherence across channels; 2) peak prominence
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e2529c96a96252dad72f46b6f2319803
https://doi.org/10.1101/2021.08.15.456413
https://doi.org/10.1101/2021.08.15.456413
Autor:
Bruce Hopenfeld
Publikováno v:
Journal of Medical Engineering & Technology. 38:317-327
Most existing heart beat detection algorithms serially process peaks, which can be either noise or true beats. Serial processing can result in inaccurate detections in the context of high noise. The proposed method relies on the relative regularity o
Publikováno v:
Annals of Biomedical Engineering. 40:2627-2638
This study investigates the performance of a new statistically driven acute ischemia detection algorithm that can process data from two bipolar cutaneous or subcutaneous leads. During a start-up phase, the algorithm processes electrocardiogram signal
Autor:
Bruce Hopenfeld, Hiroshi Ashikaga
Publikováno v:
Annals of Biomedical Engineering. 38:1060-1070
The electrophysiological basis underlying the genesis of the U wave remains uncertain. Previous U wave modeling studies have generally been restricted to one or two dimensional geometries, and it is not clear whether the U waves generated by these mo
Publikováno v:
Annals of Biomedical Engineering. 35:1771-1781
This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart
Autor:
Bruce Hopenfeld, Jeffrey H. Omens, Eric S. Leifer, Hiroshi Ashikaga, Benjamin A. Coppola, Elliot R. McVeigh
Publikováno v:
Journal of the American College of Cardiology. 49(8):909-916
Transmural Dispersion of Myofiber Mechanics: Implications for Electrical Heterogeneity In VivoHiroshi Ashikaga, Benjamin A. Coppola, Bruce Hopenfeld, Eric S. Leifer, Elliot R. McVeigh, Jeffrey H. O...
Publikováno v:
Annals of Biomedical Engineering. 33:1743-1751
In order to relate the structure of cardiac tissue to its passive electrical conductivity, we created a geometrical model of cardiac tissue on a cellular scale that encompassed myocytes, capillaries, and the interstitial space that surrounds them. A