Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Bruce A. Rathbone"'
Publikováno v:
Health Physics. 112:364-375
Radiation survey meters and personal dosimeters are typically calibrated in reference neutron fields based on conventional radionuclide sources, such as americium-beryllium (Am-Be) or californium-252 (Cf), either unmodified or heavy-water moderated.
Publikováno v:
Radiation Physics and Chemistry. 123:87-96
The radioactive isotope Californium-252 (252Cf) is relied upon internationally as a neutron calibration source for ionizing radiation dosimetry because of its high specific activity. The source may be placed within a heavy-water (D2O) moderating sphe
Autor:
Matthieu Duluc, Rick Cummings, Joetta Goda, Randy Sullivan, Thomas Zieziulewicz, David Hickman, Bruce A. Rathbone, Rashelle Will, Tim Beller, Francois Trompier, Jennifer Burch, K. G. Veinot, D Heinrichs, Milan S. Gadd, Chris Wilson, Doug McAvoy, Dann Ward
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b51547c04a4813480b7dee3042498b03
https://doi.org/10.2172/1171342
https://doi.org/10.2172/1171342
Autor:
Bruce A. Rathbone
The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::54f4b392ddbe425165a301c7a5c987d7
https://doi.org/10.2172/1010869
https://doi.org/10.2172/1010869
Autor:
Robin L. Hill, Bruce A. Rathbone
The current method at Hanford for dealing with the results from multiple dosimeters worn during non-uniform irradiation is to use a compartmentalization method to calculate the effective dose (E). The method, as documented in the current version of S
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b952d7f13875dd56dda574e4343b9222
https://doi.org/10.2172/1028093
https://doi.org/10.2172/1028093
The Pacific Northwest National Laboratory (PNNL) conducted neutron measurements at Hanford’s Plutonium Finishing Plant (PFP). The measurements were performed to evaluate the performance of the Hanford Standard Dosimeter (HSD) and the 8816 TLD compo
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::bcd5c7ee859977788555b4ecdaa51959
https://doi.org/10.2172/969172
https://doi.org/10.2172/969172
Publikováno v:
Radiation protection dosimetry. 101(1-4)
An overview is presented of the dosimetry system, dose equivalent calculation methodology, and QA/QC practices used at the US Department of Energy Hanford site. It describes some of the problems encountered in accurately measuring dose equivalent qua
This technical document provides details of derived correction factors for the Eberline R0-20 survey meter, which uses an ionization chamber to measure ambient exposure rates. A thin end window allows the instrument to measure exposure rates from non
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6b5655c9e57fcbaadf536cd70394bce1
https://doi.org/10.2172/786805