Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Brown Joshua David"'
Autor:
S. Barik, Brown Joshua David, Vincent Chan, A. J. Fernandes, D. Liu, Q. Gao, P. P.-T. Chen, M. Wintrebert-Fouquet, I. Mann
Publikováno v:
Light-Emitting Devices, Materials, and Applications.
The low growth temperature technology Remote Plasma Chemical Vapour Deposition (RPCVD) is currently being developed by BluGlass Ltd. for use in high-brightness LED applications. The unique growth conditions of RPCVD are demonstrated to produce Activa
Autor:
S. Brück, Jason P Evans, James E. Downes, Brown Joshua David, David L Cortie, Frank Klose, Xiaolin Wang, Thomas Saerbeck, Helmut Fritzsche
Publikováno v:
Physical Review B. 89
Polarized neutron reflectometry and x-ray reflectometry were used to determine the nanoscale magnetic and chemical depth profiles of the heavy rare-earth nitrides HoN, ErN, and DyN in the form of 15- to 40-nm-thick films. The net ferromagnetic compon
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Per-Anders Glans, James E. Downes, Bruce C. C. Cowie, J.-H. Guo, Lars Thomsen, C. J. McMahon, Brown Joshua David, Anton Tadich
Publikováno v:
Applied Physics Letters. 100:072108
The electronic structure of thin film HoN has been studied using soft x-ray spectroscopy. The combination of soft x-ray emission, x-ray absorption, and photoemission techniques yields direct evidence for hybridization between the N 2p and the Ho 4f s
Autor:
Richard P. Mildren, Andrew Lehmann, Adam Bramble, Benjamin F. Johnston, Leigh Weston, David J. Spence, Brown Joshua David, Eduardo Granados, James E. Downes
Publikováno v:
Optical Materials Express. 1:576
We report graphite-free laser etching of diamond surfaces using 266 nm laser pulses for a wide range of incident fluences below the threshold for ablation. The etching rate is proportional to the (fluence)x where x = 1.88 ± 0.16 over the range 10−
Autor:
Brown Joshua David
Publikováno v:
X-Rays and Their Applications ISBN: 9781461344001
If the output of an x-ray tube is examined, it will be found to contain various wavelengths of radiation, and in fact a detailed investigation shows the output to consist of a continuous range of wavelengths with very high intensities at certain disc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::611ca38daef4b7be7250495f61bb7176
https://doi.org/10.1007/978-1-4613-4398-1_7
https://doi.org/10.1007/978-1-4613-4398-1_7
Autor:
Pauly NJ; Institute for Pharmaceutical Outcomes and Policy (IPOP), University of Kentucky College of Pharmacy, 789 S. Limestone, Lexington, KY 40536 USA., Talbert JC; Institute for Pharmaceutical Outcomes and Policy (IPOP), University of Kentucky College of Pharmacy, 789 S. Limestone, Lexington, KY 40536 USA., Brown JD; Institute for Pharmaceutical Outcomes and Policy (IPOP), University of Kentucky College of Pharmacy, 789 S. Limestone, Lexington, KY 40536 USA.
Publikováno v:
Drugs - real world outcomes [Drugs Real World Outcomes] 2015; Vol. 2 (4), pp. 411-419. Date of Electronic Publication: 2015 Dec 01.