Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Brian J. Yasuda"'
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 49:915-923
Forward looking infrared (FLIR) detector arrays generally produce spatially undersampled images because the FLIR arrays cannot be made dense enough to yield a sufficiently high spatial sampling frequency. Multi-frame techniques, such as microscanning
Publikováno v:
Applied optics. 37(8)
During the process of microscanning a controlled vibrating mirror typically is used to produce subpixel shifts in a sequence of forward-looking infrared (FLIR) images. If the FLIR is mounted on a moving platform, such as an aircraft, uncontrolled ran
Publikováno v:
SPIE Proceedings.
A Kalman filter is developed to estimate the temporal drift in the gain and the offset of detectors in focal-plane array sensors from scene data. The novelty of this approach is that the gain and the offset are modeled by random sequences (state vari
Publikováno v:
SPIE Proceedings.
It is well known that non-uniformity noise in focal-plane array (FPA) sensors, which is due to the pixel-to-pixel variation in the detectors' responses, can considerably degrade the quality of images since it results in a fixed pattern that is superi
Publikováno v:
Infrared Imaging Systems: Design, Analysis, Modeling, and Testing VIII.
Forward looking infrared (FLIR) detector arrays generally produce spatially undersampled images because the FLIR arrays can not be made dense enough to yield a sufficiently high spatial sampling frequency. Multi-frame techniques, such as microscannin
Publikováno v:
Applied Optics. 39:1241
We describe a new, to our knowledge, scene-based nonuniformity correction algorithm for array detectors. The algorithm relies on the ability to register a sequence of observed frames in the presence of the fixed-pattern noise caused by pixel-to-pixel
Publikováno v:
Applied Optics. 38:772
A statistical algorithm has been developed to compensate for the fixed-pattern noise associated with spatial nonuniformity and temporal drift in the response of focal-plane array infrared imaging systems. The algorithm uses initial scene data to gene
Autor:
Brian J. Yasuda
Laboratory imaging performance tests were conducted on two Rome Air Development Center (RADC) 160x244 Platinum Silicide (PtSi) Sensors. Both cameras were tested using their RS-170 analog composite video outputs. Digital posts were not available for b
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::03ddeed6350ab3843a7d645633fe9248
https://doi.org/10.21236/ada199323
https://doi.org/10.21236/ada199323
Autor:
Brian J. Yasuda, Leo O. Vroombout
Publikováno v:
SPIE Proceedings.
Calibrated thermal imagers are being used more frequently than non-imaging radiometers to gather target and background infrared signature data. Current radiometric calibration guidelines should be expanded to include tests specifically designed for i
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.