Zobrazeno 1 - 10
of 16
pro vyhledávání: '"Brian E. Pape"'
Autor:
Brian E. Pape
Publikováno v:
Journal of Analytical Toxicology. 1:46-53
An electrolytic conductivity detector (EICD) may be used to achieve the chlorine-selective detection of organochlorlne volatiles (CH2CI 2, CHCI3, CICH2CH2CI, CCI4) separated by gas chromatography (GC). GC retention indices, "pattern recognition" of E
Publikováno v:
Therapeutic Drug Monitoring. 5:473-478
The reactivity of EMIT serum barbiturate assay reagents toward barbiturate test compounds was investigated. Reactivity was determined by the C5 substituents on the barbiturate ring and O/S substitution (barbituric/thiobarbituric acid derivatives). Re
Autor:
Brian E. Pape, Michael A. Ribick
Publikováno v:
Journal of Chromatography A. 136:113-126
An improved electrolytic conductivity detector allowed the gas-liquid chromatographic analysis of medazepam, diazepam, and major metabolites in 2 ml plasma at concentrations of 20 microgram/l. The detector had a sensitivity limit of less than 1 ng (o
Autor:
Brian E. Pape
Publikováno v:
Journal of Analytical Toxicology. 5:113-117
A new metabolite of haloperidol, formed by what is equivalent to the reduction of the carbonyl group to the alcohol, has been identified in human serum, liver and urine. The isolation and chromatographic behavior of the compound are discussed.
Publikováno v:
Therapeutic Drug Monitoring. 5:467-472
Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay c
Autor:
Matthew J. Zabik, Brian E. Pape
Publikováno v:
Journal of Agricultural and Food Chemistry. 20:316-320
Autor:
Matthew J. Zabik, Brian E. Pape
Publikováno v:
Journal of Agricultural and Food Chemistry. 20:72-75
Publikováno v:
Journal of Agricultural and Food Chemistry. 19:308-313
Publikováno v:
The American Journal of Cardiology. 43:860-862
To assess the problem of continuing propranolol therapy in a breast-feeding mother, studies were performed to determine simultaneously plasma and breast milk concentrations of propranolol after single dose (40 mg) and continuous dose (40 mg 4 times d
Publikováno v:
Journal of chromatography. 134(1)
The response and elemental selectivity of the electrolytic conductivity detector (EICD) to nitrogen-, chlorine-, and sulfur-containing compounds has been investigated as-a function of chemical structure, furnace chemistry conditions (i.e., reaction g