Zobrazeno 1 - 10
of 29
pro vyhledávání: '"Bratimir Panić"'
Publikováno v:
Materials Chemistry and Physics. 124:109-112
The effect of hydrostatic pressure on R line position and fluorescence lifetime τ for R line (2E → 4A2 transition) in LMA:V2+ (LaMgAl11O19:V2+) was considered in the 0–100 kbar pressure range. Position of the R line is insensitive to pressure in
Autor:
Branka Murić, Svetlana Savić-Šević, Larisa Blažić, Ilija Belic, Dejan Pantelić, Bratimir Panić
Publikováno v:
Lasers in Medical Science. 26:179-186
The purpose of this research was to investigate the influence of modulated photoactivation on cuspal movement. Eight class II MOD composite restorations were analyzed under various photoactivation protocols in a real-time manner using holographic int
Publikováno v:
Materials Research Bulletin. 45:186-189
The effect of hydrostatic pressure (varying up to 91 kbar) at room temperature emission spectra and fluorescence lifetime of the Cr 3+ R1 line ( 2 E → 4 A 2 transition) in tiospinel ZnAl 2 S 4 was studied for the first time. The studies performed r
Autor:
Dejan Pantelić, Svetlana Savić-Šević, Darko Vasiljević, Branka Murić, Marko Nikolić, Larisa Blažić, Bratimir Panić
Publikováno v:
Materials and Manufacturing Processes. 24:1142-1146
We have developed a real-time holographic technique to observe deformation induced by dental composite contraction. The standard split beam method was used, in conjunction with in situ holographic plate processing. Experiments were performed on a mec
Publikováno v:
Optical Materials. 30:1217-1220
Photosensitivity of tot’hema and eosin sensitized gelatin layer (TESG) is analyzed. Tot’hema is a trade name of a drinkable solution used in medicine for treatment of anemia, while eosin is an organic dye, used in medicine too. The resulting mate
Publikováno v:
Acta Physica Polonica A. 112:993-999
Imaging properties of the concave microlens are presented. Microlenses are produced by using tot’hema eosin sensitized gelatin and 532 nm laser irradiation (2nd Nd:YAG harmonic). Imaging properties of microlenses are analized by calculation: the RM
Autor:
M. Minić, Bratimir Panić, M. Mijailović, M. Obradović, Zoran D. Grujić, Branislav M. Jelenkovic, Aleksandar Kovačević, Stefka Cartaleva
Publikováno v:
Acta Physica Polonica A. 112:799-803
We investigated effects of spatially separated laser fields on amplitudes and widths of electromagnetically induced transparency in M-type atomic system. We have shown narrowing of the electromagnetically induced transmission resonance and therefore
Autor:
D. Pantelić, Ilija Belic, Branka Murić, Svetlana Savić-Šević, Bratimir Panić, Larisa Blažić, Darko Vasiljević
Publikováno v:
Acta Physica Polonica A. 112:1157-1160
Polymerization contraction of dental photo-polymer composites induces internal stress, in a tooth cavity. This stress is measured indirectly by, first, holographic determination of tooth deformation, with consequent calculation of stress using finite
Autor:
Jelena Dimitrijević, B. M. Jelenković, D. Arsenović, M. Mijailović, Bratimir Panić, Zoran D. Grujić
Publikováno v:
Acta Physica Polonica A. 112:841-845
Publikováno v:
Review of Scientific Instruments. 74:3155-3159
An electronic system used for active control and optical frequency stabilization of a He–Ne laser is described. It is based on digital acquisition and signal processing, using minimum of analog electronics, and a personal computer (PC). Main functi